Drehgeber RMS20
- ●Um einen Kauf zu tätigen, wenden Sie sich an die Verteiler
oder nutzen Sie den stehenden Online-Shops unten.
Verkaufskanal Überprüfen Sie die Verteiler.- VERKAUFSKANALKlicken Sie hier, um den Verteiler zu überprüfen.
250P/R, 256P/R so easy setting
- High resolution of 256 P/R and fine setting
- Lower consumption of electric power (15 mA maximum) due to magnetic method
- Long life for 105 times continuous run due to contactless & magnetic method
- Square wave output (with Amp.)
- Smooth rotation for setting
- RoHS compliant
PART NUMBER DESIGNATION
RMS20 - | 250- | 2 | 0 | 1- | 1 |
---|---|---|---|---|---|
Series name |
Resolution (P/R) 100, 250, 256 |
Output phase 2:“A” & “B” |
|
|
Output connection 1:Cable wire |
LIST OF PART NUMBERS
Part number | Resolution | Input voltage |
---|---|---|
RMS20-100-201-1 | 100 (P/R) | 5 V |
RMS20-250-201-1 | 250 (P/R) | |
RMS20-256-201-1 | 256 (P/R) |
Electrical characteristics
Input voltage | DC5 V ± 5 % | |||
---|---|---|---|---|
Input current | 15 mA maximum (No load) | |||
Output wave form | Square wave | |||
Output phases | A, B | |||
Resolution (P/R) | 100 | 250 | 256 | |
Phase difference of outputs A & B | 90° ± 45° | |||
Maximum frequency response | 5 kHz | |||
Output signal | “1 (High)” | + 4.5 V minimum | ||
“0 (Low)” | + 0.5 V maximum | |||
Sensor | Magnetoresistive element |
Mechanical characteristics
Rotational torque | 4.90 mN·m {50 gf·cm} maximum | |
---|---|---|
Inertia | 3 g·cm2 maximum | |
Shaft loading (When mounting) | Radial | 9.81 N {1 kgf} maximum |
Axial | 9.81 N {1 kgf} maximum | |
Rotational life | 105 revolution | |
Net weight | Approx. 20 g | |
Strength of tighten screw | 0.49 N·m {5 kgf·cm} maximum |
Environmental characteristics
Operating temp. range | − 10 ~ 60 °C |
---|---|
Storage temp. range | − 40 ~ 70 °C |
Protection grade | IP40 |
RELIABILITY TEST
◆The output shall satisfy the criteria below after the following tests.
Test item | Test conditions | ||
---|---|---|---|
Vibration | Power OFF | Amplitude : 1.52 mm or 98.1m/s2 (10 G) whichever is smaller. 10 ~ 500 Hz excursion 15 min/cycle, 8 cycles each for X, Y, Z, directions. |
|
Shock | Power OFF | 3 times each in directions (X, Z) at 490 m/s2 (50 G), 11 ms. | |
High temperature exposure | Power OFF | 70 °C 96 h | (To be measured after leaving samples for 1 h at normal temperature and humidity after the test.) |
Power ON | 60 °C 96 h | ||
Low temperature exposure | Power OFF | − 40 °C 96 h | |
Humidity | Power OFF | 40 °C Relative humidity 90 〜 95 % 96 h(To be measured after wiping out moisture and leaving samples for 1 h at normal temperature and humidity after the test.) | |
Thermal shock | Power OFF | To be done 10 cycles with the following condition (To be measured after leaving samples for 1 h at normal temperature and humidity after the test.) 70 °C 0.5 h、− 40 °C 0.5 h |
OUTLINE DIMENSIONS
Unless otherwise specified, tolerance: ± 0.4 (Unit: mm)
OUTPUT
ELECTRICAL WIRING
OUTPUT CIRCUIT
KNOB FOR SETTING ENCODERS
※The knobs are sold separately as an optional item.
You can choose gray or black color.The hexagon socket head screws are attached. (3 pieces)
Unterlagen
- ●Die oben genannten Inhalte können ohne vorherige Ankündigung geändert werden.