Mikrogebläse TF029B-1000-F
- ●Um einen Kauf zu tätigen, wenden Sie sich an die Verteiler
oder nutzen Sie den stehenden Online-Shops unten.
Verkaufskanal Überprüfen Sie die Verteiler.- VERKAUFSKANALKlicken Sie hier, um den Verteiler zu überprüfen.
Micro Blowers TF029B-1000-F
FeaturesFeatures
-
Compact / Light weight *The smallest and lightest series
-
Aerodynamic bearings
-
High static pressures
-
Low vibration
-
Long life due to aerodynamic bearings without heat dependence
-
Resin in full compliance with FDA standards
STANDARD SPECIFICATIONS
No. | Item | TF029B-1000-F | Remarks | |
---|---|---|---|---|
1 | Rated Voltage | 12 ~ 27 VDC | ||
2 | Direction of Rotation | CCW (Counter-Clockwise) | Looking down from the air inlet. | |
3 | Kind of Gas | air | Noncorrosive gas | |
4 | Configuration | Motor with Centrifugal Blade | Without driving circuit | |
5 | Type of Motor | DC Brushless Motor | ||
6 | Number of Poles | 4 Poles (2 pole pairs) | ||
7 | Drive System | 3 Phase, Bipolar | ||
8 | Bearings | Aerodynamic Bearings | ||
9 | Impeller | Centrifugal Turbo Blade | ||
10 | Mounting Direction | Shaft vertical to ground, air inlet facing upwards | No vibration, shock, or gyration is to be applied during operation. | |
11 | Rated Rotation Speed | 36,000 r/min (reference value) | at 2.0kPa, 100L/min | |
12 | Maximum Input Coil Current | 2.0 A rms max. | ||
13 | Rated Power Supply Current | 0.62 A max. | at 2.0kPa, 100L/min, at 24V | |
14 | Rated Power Consumption | 14.9 W max. | ||
15 | Rated Air Flow | 100 L/min(圧力= 2.0 kPa at 2.0kPa) | at 2.0 kPa | |
16 | Minimum Air Flow | 10 L/min | ||
17 | Rated Pressure | 2.0 kPa | at 100 L/min | |
18 | Maximum Pressure | 3.5 kPa | absolute maximum pressure. at 24VDC | |
19 | Torque Constant | 0.0014 ~ 0.0020 N·m/A (reference value) | ||
20 | Min. Rotation Speed | 10,000 r/min | ||
21 | Maximum Rotation Speed | 50,000 r/min | Within the "Area of use" | |
22 | Acoustic Audible Noise | 65.0 dB(A)max. | at 2.0kPa, at 100L/min measured at 1m from air inlet Include background noise 15dB(A) |
|
23 | Coil Resistance | 0.37 ~ 0.49 Ω (reference value) | 20℃ (Between 2 phase) | |
24 | Coil Inductance | 22 ~ 29 μH (reference value) | 20℃,10kHz (Between 2 phase) | |
25 | Insulation Class | Class E | JIS C 4003 | |
26 | Insulation Resistance | 1M Ω min. DC500V (between terminal pins and shaft holder) | JIS C 4003 | |
27 | Dielectric Strength | Leak current to be less than 1mA. (AC600V for 1sec. between terminal pins and shaft holder.) | JIS C 4003 | |
28 | Weight | 55 g (reference value) | ||
29 | Rotor Inertia | 10 g·cm2 (reference value) | ||
30 | Axial Loading | 3N max. | maximum axial force applying to the intake (upper housing) | |
31 | Operating Temperature Range | 0 ~ 50 °C | ||
32 | Operating Humidity Range | 10 ~ 95%RH | No condensation | |
33 | Storage Temperature Range | -20 ~ 60 °C | ||
34 | Storage Humidity Range | 10 ~ 95%RH | No condensation | |
35 | Resistance to Vibration | The Blower shall satisfy Specification No.11~27 after the following test. | Non-operating | |
Kind of Vibration | frequency veering | |||
Frequency Range | 10 ~ 22Hz amplitude 1mm | |||
22 ~ 50Hz 19.6m/s2 (2G acceleration) | ||||
Sweep | to-and-fro, approx. 5min. | |||
Test Time | X, Y, Z directions, 60min. each | |||
36 | Resistance to Shock | The Blower shall satisfy Specification No.11~27 after the following test. | Non-operating | |
Acceleration | 294m/s2(30G) | |||
Pulse Width | 6ms | |||
Shock Waven | Semi-sinusoidal wave | |||
Number of Shock | X, Y, Z, directions, once per each direction |
P-Q CURVE CHARACTERISTICS
- Conditions: Ambient temperature 23±5°C, normal humidity, atmospheric pressure (100±2kPa). The graphs above is provided for reference only. Values are not guaranteed.
- Make sure the thermistor temperature does not exceed 80°C during blower operation. (Thermistor resistance value R(80 deg C)=1.177k Ω ).
INTERFACE
OUTLINE DIMENSIONS
Micro Blower Kit with driver
- For the model with mounting brackets "TF029B-1000-F", Kits with driver and wire harness for the blower available.
- They will help customers shorten their evaluation and product development times.
● Kit Part Number : TF029B-1000-P
List of the kit | |
---|---|
1 | Micro Blower (TF029B-1000-F) |
2 | Special Driver (TF029B-1001-D) |
3 | Wire Harness (for Driver-Blower connection) |
4 | Wire Harness (for Driver-Power connection) |
*The Drivers are sold separately as an optional item.
CONNECTION
*Connect the micro blower, driver, and harness as follows.
Precautions for handling
Do not give strong strass such as shock, vibration and oscillation to product. While product is working, such stress may cause Lock-up of rotor which can lead the product to permanent damage.
This product doesn't include a driver. Buyer has to install and configure a driver properly according to characteristic, rating and recommendation in this specification.
This specification doesn't mean that our guarantees Product will not be breakdown or out of order in any case. Buyer has to implement a proper protection measure on Buyer's system in preparation for sudden malfunction and out of control of Product.
Product characteristic was measured with our standard measuring equipment*1), therefore the characteristics in actual condition or use at Buyer may different from the characteristic in this specification. Checkout the characteristic results at the actual condition before use. *1) Flowmeter we using is a mass flowmeter of thermal method displaying volume flow rate at 20℃・1 air pressure.
Turn off the power of the product and any equipment attached to the product when putting on or taking off the cables.
Turn off the power immediately and stop using the product in the following cases.
1. In case water or foreign substances get into the product.
2. In case the product is dropped or the housing is broken.
3. In case unusual odor, abnormal noise, or smoke are generated from the product.
Do not use or store product where shock, vibration, static electricity might occurs and with high temperature, humidity, dust, corrosive gas, no ventilation and near splashing water, chemical material or oil.
Do not block the air inlet and outlet.
Please connect and don't use air inlet of this product in series.
Product has parts rotating at high speed which might cause serious personal injury. Pay attention to handle product while it works.
Please contact us if you have any questions regarding installation.
Warranty
Warranty period of the Product is one year from delivery. In case, defect has been found in the Product during the warranty period and it was found that NIDEC COMPONENTS (here in after referred as NCC) is responsible and liable for the defect, NCC shall either repair or replace the defected Product free of charge, provided, however, that foregoing warranty shall be voided and shall not be applied in any instances where.
1. Buyer fails to carry out proper handling, operating, installation, testing, service and checkout of the Product and/or to follow NCC’s instruction or advice with respect to any of these matters.
2. Buyer utilizes any attachments or interface devices or makes any modification to the product which are not approved in writing by NCC.
3. Buyer incorporates any parts not supplied by NCE into the Product and/or combines any equipment.not supplied by NCC with Product.
4. The alleged defect arises out of NCC’s compliance with any written request, instruction, design change, drawing or specification (including but not limited to instruction manual, installation manual, and service manual prepared by Buyer) specifically furnished or imposed by Buyer upon Seller.
5. Defect arisen due to reason that it has been unable to be aware of the problem by ordinary scientific and technical knowledge and capability in those days.
6. Failure or damage caused by natural disaster, fire or unavoid able factors.
In addition, NCC shall not indemnify Buyer against any damages and losses which are alleged to have arisen as a result of and/or caused by defect or malfunction of Product. Buyer must implement a proper protection measure on Buyer’s system in preparation for sudden malfunction and out of control of Product.
Disclaimer
The product is not designed for use in equipment or devices that could have an impact on life or body, or those that could damage property (These include, but are not limited to, medical equipment, disaster prevention equipment, security equipment, combustion control equipment, infrastructure control equipment, vehicle equipment, transportation equipment, on-board equipment, aviation equipment, space equipment, and nuclearrelated equipment). If you want to use this product for any of the above-mentioned equipment or devices, be sure to contact our point of contact beforehand. The details of warrant y shall be as per the descriptions in this document and we shall not be liable for any damage on you resulting from the use of any equipment or device (including control systems) which is not in accordance with this document (hereinafter referred to as "use in violation"). In the case where you resell our products, we shall not be liable for any damage on a third party resulting from use in violation by the third party, and even if we make payment to the third party in connection with such use in violation regardless of the name by which such payment may be called, we may demand the whole amount thereof from you.
This product is strictly prohibited from using, providing or exporting for the purposes of the development of weapons of mass destruction or military use. We are not liable for any losses, damages, claims or demands caused by any provision or export to the person or entity who intends to develop, manufacture, use or store nuclear, biological or chemical weapons or missiles, or use any other military purposes.
All the information described herein(product data, specifications, figures, tables, programs and application circuit examples, etc) is current as of publishing date of this document and is subject to change without notice.
This specification doesn’t mean that NCC guarantees Product will not be breakdown, out of order and fail in any case. Buyer has to therefore take responsibility to give thorough consideration to safety design to prevent accidents causing injury or damage that may ensue from the Product’s failure or malfunction. The entire system in which the Product is used must be sufficiently evaluated and judged whether the Product operates without problems. We are not liable for losses, damages, claims or demands which are claimed to have arisen as a result of and caused directly or indirectly by Product’s defect, out of order, failure and malfunction.
Unterlagen