Pressure Sensors / Pressure Switches
Series:Pressure transducer P-2000
Pressure medium | Non-corrosive gases |
---|---|
Port Size | Φ3.2mm Tube |
Pressure Type | Gauge |
Pressure range | 0~9.81, 0~49.0, 0~98.1, 0~343,0~490, 0~686, 0~981 kPa |
Power | 1.5mA Constant current |
Output | 90±30 mV |
- Documents
Series:Pressure transducer P-3000S
Pressure medium | Non-corrosive gases |
---|---|
Port Size | Φ3.5mm Tube |
Pressure Type | Gauge / Differential / Absolute |
Pressure range | 0~4.9 kPa,0~9.81 kPa,0~49.0 kPa,0~98.1 kPa,0~490 kPa,0~686 kPa,±9.81 kPaD,±49.0 kPaD,±98.1 kPaD,0~34.3 kPa (abs),0~98.1 kPa (abs) |
Power | 1.5mA Constant current |
Output | 70±30 mV,50±20 mV,100±30 mV,50±20 mV,80±40 mV |
- Documents
Series:Pressure transducer P-8300
Pressure medium | Corrosive gases/liquids compatible with SUS316L |
---|---|
Port Size | Φ19.8 mm |
Pressure Type | Gauge / Absolute |
Pressure range | 0~49.0 kPa,0~98.1 kPa,0~343 kPa,0~981 kPa,0~34.3 kPa (abs),0~98.1 kPa (abs) |
Power | 1.5mA Constant current |
Output | 100 ±50 mV |
- Documents
Series:Pressure transducer P-8305
Pressure medium | Corrosive gases/liquids compatible with SUS316L |
---|---|
Port Size | Φ27.1 mm |
Pressure Type | Gauge |
Pressure range | 0~10 kPa |
Power | 1.5mA Constant current |
Output | 25±10 mV |
- Documents
Series:Pessure transducer P-8505
Pressure medium | Corrosive gases/liquids compatible with SUS316L |
---|---|
Port Size | Φ17.5 mm |
Pressure Type | Gauge |
Pressure range | 0~50 kPa,0~100 kPa,0~350 kPa,0~1000 kPa |
Power | 1.5mA Constant current |
Output | 90±30 mV |
- Documents
Series:Pressure transducer (ratio metric) P-7100
Features | Ultra-compact and lightweight using Retiometric |
---|---|
Pressure medium | Corrosive gases/liquids compatible with SUS304, SUS316L |
Pressure range | 0~100kPa, -100~100kPa, 0~1MPa, 0~133.3kPa abs |
Supply voltage | 5±0.5V DC |
Output | 0.5~4.5V DC (ratio metric) |
Pressure port | R1/8, M5 female |
- Documents
Series:Pressure transducer with amp. PA-20
Pressure medium | Non-corrosive gases |
---|---|
Pressure Type | Gauge |
Pressure range | -100~0kPa, -100~300 kPa |
Supply voltage | 10.8 ~ 30 VDC |
Output | 1 ~ 5 VDC |
Pressure port | 2-M5 female/M5 male |
- Documents
Series:Pressure transducer with amp. PA-100
Pressure medium | Non-corrosive gases |
---|---|
Pressure Type | Differential |
Pressure range | 0 ~ 1 kPa,0 ~ 2 kPa,0 ~ 5 kPa,± 1 kPa,± 2 kPa,±5 kPa |
Supply voltage | 5 VDC |
Output | 0.5 ~ 4.5 VDC |
Pressure port | Φ2.5 mm |
- Documents
Series:Pressure transducer with amp. PA-500
Pressure medium | Non-corrosive gases / liquids |
---|---|
Pressure Type | Gauge |
Pressure range | 0 ~ 9.81 kPa,0 ~49 kPa,0 ~ 98.1 kPa,0 ~ 343 kPa,0 ~ 490 kPa,0 ~ 981kPa,−100 ~ 0 kPa |
Supply voltage | 12 ~ 24 VDC |
Output | 1 ~ 5 VDC |
Pressure port | R 1/4,G 1/4 |
- Documents
Series:Pressure transducer with amp. PA-750
Pressure medium | Corrosive gases/liquids compatible with SUS304, SUS316L |
---|---|
Pressure Type | Gauge / Absolute |
Pressure range | 0 ~ 100 kPa,0 ~ 350 kPa,0 ~ 1.0 MPa,0 ~ 3.5 MPa,−100 ~ 0 kPa,−100 ~ 100 kPa,−100 ~ 300 kPa,0 ~ 100 kPa(abs) |
Supply voltage | 10.8 ~30 VDC |
Output | 1 ~ 5 VDC |
Pressure port | R1/8,R1/4 |
- Documents
Series:Pressure transducer with amp. PA-758
Pressure medium | Corrosive gases/liquids compatible with SUS304, SUS316L |
---|---|
Pressure Type | Gauge / Absolute |
Pressure range | 0 ~ 100 kPa,0 ~ 350 kPa,0 ~ 1.0 MPa,0 ~ 3.5 MPa,−100 ~ 0 kPa,−100 ~ 100 kPa,−100 ~ 300 kPa,0 ~ 100 kPa(abs) |
Supply voltage | 24 VDC |
Output | 4 ~ 20mA |
Pressure port | R1/8,R1/4 |
- Documents
Series:Pressure transducer with amp. PA-800
Pressure medium | Corrosive gases/liquids compatible with SUS316L or SUS316 |
---|---|
Pressure Type | Gauge |
Pressure range | 0 ~ 98.1 kPa,0 ~ 343 kPa,0 ~ 981 kPa,−98.1 ~ 0 kPa |
Supply voltage | 12 ~ 24 VDC |
Output | 1 ~ 5 VDC |
Pressure port | G 3/8 |
- Documents
Series:Pressure transducer with amp. PA-830
Pressure medium | Corrosive gases/liquids compatible with SUS316L |
---|---|
Pressure Type | Gauge / Absolute |
Pressure range | 0 ~ 9.8 kPa,0 ~ 49.0 kPa,0 ~ 98.1 kPa,0 ~ 343 kPa,0 ~ 981 kPa,−100 ~ 0 kPa,0 ~ 34.3 kPa (abs),0 ~ 98.1 kPa (abs) |
Supply voltage | 12 ~ 24 VDC |
Output | 1 ~ 5 VDC |
Pressure port | G 1/8,R 1/4,1/4 VCR |
- Documents
Series:Pressure transducer with amp. PA-838
Pressure medium | orrosive gases/liquids compatible with SUS316L |
---|---|
Pressure Type | Gauge |
Pressure range | 0 ~ 49.0 kPa,0 ~ 98.1 kPa,0 ~ 981 kPa |
Supply voltage | 24 VDC |
Output | 4 ~ 20 mA |
Pressure port | G 1/8,R 1/4,1/4 VCR |
- Documents
Series:Pressure transducer with amp. PA-838-D
Features | Differential pressure sensor for liquid |
---|---|
Pressure medium | Corrosive gases / liquids compatible with SUS304 |
Pressure Type | Differential |
Pressure range | 0 ~ 10 kPaD, 0 ~ 50 kPaD, 0 ~ 100 kPaD |
Supply voltage | 24 VDC |
Output | 4 ~ 20 mA |
Pressure port | 2 - Rc 1/4, 2 - 1/4 Flare fitting (7/16 - 20 UNF) |
Protective construction | Drip-proof construction with IP65 |
- Documents
Series:Pressure transducer with amp. PA-840
Pressure medium | Gas and liquid which does not corrode SUS316L/Gas and liquid which does not corrode O-ring (Fluoro rubber) G2 Fitting |
---|---|
Pressure Type | Gauge/Absolute |
Pressure range | -0.1~0.1 MPa,-0.1~0.35 MPa,0~1.0 MPa,0~3.5MPa,0~0.1MPa abs. |
Supply voltage | 10.8~26.4V DC (Including ripple) |
Output | 1 ~ 5 V |
Pressure port | R 1/4, G 1/4 |
Protection | IP67 |
- Documents
Series:Pressure transducer with amp. PA-848
Pressure medium | Gas and liquid which does not corrode SUS316L/Gas and liquid which does not corrode O-ring (Fluoro rubber) G2 Fitting |
---|---|
Pressure Type | Gauge/Absolute |
Pressure range | -0.1~0.1 MPa,-0.1~0.35 MPa,0~1.0 MPa,0~3.5MPa,0~0.1MPa abs. |
Supply voltage | 21.6~26.4 V DC (Including ripple) |
Output | 4~20 mA DC |
Pressure port | R 1/4, G 1/4 |
Protection | IP67 |
- Documents
Series:Pressure transducer with amp. PA-850
Pressure medium | Corrosive gases/liquids compatible with SUS316L |
---|---|
Pressure Type | Gauge / Absolute |
Pressure range | 0 ~ 100 kPa,0 ~ 350 kPa,0 ~ 1000 kPa,−100 ~ 0 kPa,−100 ~ 100 kPa,−100 ~ 300 kPa,0 ~ 100 kPa (abs) |
Supply voltage | 12 ~ 24 VDC |
Output | NPN/PNP open collector output 1 and 1 ~ 5 VDC |
Pressure port | R 1/4,G 3/8,G 1/4 |
- Documents
Series:Pressure transducer with amp. PA-858
Pressure medium | Corrosive gases/liquids compatible with SUS316L |
---|---|
Pressure Type | Gauge / Absolute |
Pressure range | 0 ~ 100 kPa,0 ~ 350 kPa,0 ~ 1000 kPa,−100 ~ 0 kPa,−100 ~ 300 kPa,0 ~ 100 kPa (abs) |
Supply voltage | 24 VDC |
Output | 4 ~ 20 mA |
Pressure port | R 1/4,G 3/8,G 1/4 |
- Documents
Series:Pressure transducer with amp. PA-860
Pressure medium | Hydraulic oil |
---|---|
Pressure Type | Gauge |
Pressure range | 0 ~ 5MPa,0 ~ 10MPa,0 ~ 20MPa,0 ~ 35MPa |
Supply voltage | 12 ~ 24 VDC |
Output | 1 ~ 5 VDC |
Pressure port | R 1/4,G 3/8 |
- Documents
Series:Pressure transducer with amp. PA-868
Pressure medium | Hydraulic oil |
---|---|
Pressure Type | Gauge |
Pressure range | 0 ~ 5MPa,0 ~ 10MPa,0 ~ 20MPa,0 ~ 35MPa |
Supply voltage | 12 ~ 24 VDC |
Output | 4 ~ 20 mA |
Pressure port | R 1/4,G 3/8 |
- Documents
Series:Pressure transducer for high vacuum PA-920S/928S
Features |
Compact size, Full penetration weld, |
---|---|
Pressure medium | No corrosive capability to SUS316L Gases and Liquids (Double-Melt Material) |
Pressure Type | Gauge (Positive) / Compound |
Pressure range | 0~0.5, 0~1,-0.1~0.5, -0.1~1 MPa |
Supply voltage | PA-920S: 12~24 V ±10% (Voltage output) PA-928S: 24 V ±10% (Current output) |
Analog output | PA-920S: 1~5 V / PA-928S: 4~20 mA |
Pressure port | 1.125" W-Seal, 1.125" C-Seal |
Protection | IP40 |
Remarks
|
Since this series is made to order, please contact us separately. |
- ●To buy this product, please contact Sales Reps, Distributors.
Series:Pressure transducer for high temperature PA-930
Features | Suitable for high temperature media (150 °C) |
---|---|
Pressure medium | Corrosive gases/liquids compatible with SUS316L and nickel alloy |
Pressure Type | Gauge |
Pressure range | 0 ~ 100 kPa,−100 ~ 100 kPa,−100 ~ 300 kPa,0 ~ 1000 kPa,−100 ~ 0 kPa |
Supply voltage | 12 ~ 24 VDC |
Output | 1 ~ 5 VDC |
Pressure port | 9/16-18UNF,R 1/4 |
- Documents
Series:Pressure transducer for high temp. PA-930-A [Absolute]
Features | Absolute pressure sensors suitable for high temperature media (150 °C) |
---|---|
Pressure medium | Corrosive gases/liquids compatible with SUS316L and nickel alloy |
Pressure Type | Absolute |
Pressure range | 0 ~ 100 kPa (abs),0 ~ 200 kPa (abs) |
Supply voltage | 12 ~ 24 VDC |
Output | 1 ~ 5 VDC |
Pressure port | 9/16-18UNF |
- Documents
Series:Pressure transducer for high pressure range PA-97S
Features |
Thin film pressure sensor using SUS diaphragms equivalent, wide media temp. range: -40~125 °C |
---|---|
Pressure medium | Corrosive gases / liquids compatible with SUS630 |
Pressure reference | Gauge |
Pressure range | 0 ~ 1 / 2 / 3.5 / 5 / 10 / 20 / 35 / 40 / 50 / 80 MPa |
Supply voltage | PA-970S / 972S / 978S: 9~36 V, PA-971S: 5 V ±10 %, PA-973S: 14~36 V |
Analog output | PA-970S: 1~5 V / 972S: 0~5 V / 973S: 0~10 V / 971S: 0.5~4.5 V (Ratiometric) / PA-978S: 4~20 mA |
Fitting | G 1/4, G 3/8, R 1/4 |
Approvals | UL recognized, CE marking applicable |
Connector cable | *Sold separately,
*Sold separately,
Voltage output cable / Current output cable |
Remarks | ⇒ Learn more to the Product details page. |
- ●To buy this product, please contact Sales Reps, Distributors.
Series:Pressure switch PS20
Pressure medium | Non-corrosive gases |
---|---|
Pressure reference | Gauge |
Pressure range | -100~0, -100~300 kPa |
Power | 10.8~30 V DC |
Output | NPN/PNP open collector output 1 |
Pressure port | 2-M5 female screw,M5 male screw |
- Documents
Series:Pressure switch PS30
Pressure medium | Non-corrosive gases |
---|---|
Pressure reference | Gauge |
Pressure range | -100~100kPa, -100~1000 kPa |
Power | 12 ~ 24 VDC |
Output | NPN/PNP open collector output 2 |
Pressure port | M5 female |
- Documents
Series:Pressure switch PS40
Pressure medium | Non-corrosive gases |
---|---|
Pressure reference | Gauge |
Pressure range | -100~0kPa, 0~50 kPa,0 ~ 100 kPa,0 ~ 1000 kPa |
Power | 10.8 ~ 30 VDC |
Output | NPN/PNP open collector output and 1 ~ 5 VDC, or output 2 |
Pressure port | R1/8 male,M5 female |
- Documents
Series:Pressure switch PS6
Pressure medium | Non-corrosive gases |
---|---|
Pressure reference | Gauge |
Pressure range | -100~0 kPa, 0 ~ 100 kPa, 0 ~ 1000 kPa |
Power | 12 ~ 24 VDC |
Output | NPN/PNP open collector output and 1 ~ 5 VDC, or output 2 |
Pressure port | R1/8 male, M5 female |
- Documents
Series:Pressure switch PS60
Pressure medium | Non-corrosive gases |
---|---|
Pressure reference | Gauge |
Pressure range | -100~100 kPa, -100~300 kPa, -100 ~ 1000 kPa |
Power | 12 ~ 24 VDC |
Output | NPN/PNP open collector output 2 |
Pressure port | M5 female |
- Documents
Series:Pressure switch PS8
Pressure medium | Corrosive gases/liquids compatible with SUS316L or SUS316 |
---|---|
Pressure reference | Gauge |
Pressure range | 0 ~ 98.1 kPa, 0 ~ 343 kPa, 0 ~ 981 kPa, -98.1 ~ 0 kPa |
Power | 12 ~ 24 VDC |
Output | NPN open collector output 2 |
Pressure port | G 3/8 |
- Documents
Series:Pressure switch PS83
Pressure medium | Corrosive gases/liquids compatible with SUS316L |
---|---|
Pressure reference | Gauge / Absolute |
Pressure range | 0 ~ 49.0 kPa, 0 ~ 98.1 kPa, 0 ~ 343 kPa, 0 ~ 981 kPa, -98.1 ~ 0 kPa, 0 ~ 34.3 kPa (abs), 0 ~ 98.1 kPa (abs) |
Power | 12 ~ 24 VDC |
Output | NPN open collector output 2 |
Pressure port | G 1/8, R 1/4, 1/4 VCR |
- Documents
Series:Pressure switch PS85
Pressure medium | Corrosive gases/liquids compatible with SUS316L |
---|---|
Pressure reference | Gauge / Absolute |
Pressure range | -100 ~ 100 kPa, -100 ~ 350 kPa, -100 ~ 1000 kPa, 0 ~ 100 kPa (abs) |
Power | 10.8 ~ 30 VDC |
Output | NPN/PNP open collector output 2 |
Pressure port | R 1/4, G 3/8, G 1/4 |
- Documents
Series:Pressure switch PS86
Pressure medium | Hydraulic oil |
---|---|
Pressure reference | Gauge |
Pressure range | 0 ~ 5 MPa, 0 ~ 10 MPa, 0 ~ 20 MPa, 0 ~ 35 MPa |
Power | 12 ~ 24 VDC |
Output | Open collector output insulated by a photocoupler output 1 |
Pressure port | R 1/4, G 3/8 |
- Documents
Series:Pressure switch for high vacuum PS91
Pressure medium | Corrosive gases/liquids compatible with SUS316L |
---|---|
Pressure reference | Gauge |
Pressure range | -100 ~ 10 kPa |
Power | 12 ~ 24 VDC |
Output | NPN/PNP open collector output 2 |
Pressure port | Gasket joint 9/16-18UNF |
- Documents
Series:Pressure switch for high pressure range PS97
Features |
Thin film pressure switch using SUS diaphragms equivalent, wide media temp. range: -40~125 °C |
---|---|
Pressure medium | Corrosive gases / liquids compatible with SUS630 |
Pressure reference | Gauge |
Pressure range | 0 ~ 1.0 / 2.5 / 5.0 / 10 / 25 / 40 / 80 MPa |
Supply voltage | 9 ~ 36 V |
Switch output | NPN open collector output 2, or output 1 |
Fitting | G 1/4, R 1/4 |
Approval | UL recognized, CE marking applicable |
Connector cable | Sold separately: DT Cable / M12 Cable |
Attention | Operating mode and the Pressure setting point to operate switch must be set beforehand according to your wish, Hysteresis can be also set arbitrarily. ⇒ Learn more. |
- Documents
- ●To buy this product, please contact Sales Reps, Distributors.
Series:Pressure gauge for high vacuum PG-20
Features | UL991 tested, third party test report available(PNP open collector type only) UL508 recognized, CE marking applicable Easily installable by fitting block Rotable display and external diameter φ 20 mm Integrally welded structure of sensing chip and fitting block |
---|---|
Pressure medium | Gases and Liquids compatible with SUS316L |
Pressure reference | Gauge / Compound |
Pressure range | 0~0.5, 0~1.0, -0.1~0.5, -0.1~1.0 MPa |
Power | 12~24 VDC |
Output | NPN/PNP open collector output 2 / output 1 and 1~5 VDC/4~20 mA |
Pressure port | 1.5 inch W seal / 1.125 inch W seal |
- Documents
Series:Pressure gauge PG-30
Pressure medium | Non-corrosive gases |
---|---|
Pressure reference | Compound |
Pressure range | -10~10, -100~100, -100~1000 kPa |
Power | 10.8~30 VDC |
Output | 2 switch output (NPN/PNP open collector) and 1~5 VDC analog output |
Pressure port | 2-RC 1/8 |
Accuracy | Analog output: ± 3 %FS,Switch output: ± 3 %FS |
Display | Full 3-digit LED |
Ingress Protection | IEC IP65 |
Approval | UL recognized,CE marking applicable |
Setting method | Click the YouTube button on the left.Please see the easy-to-understand setting operation procedure in the video. |
- Documents
Series:Pressure gauge PG-35
Pressure medium | Non-corrosive gases / liquids |
---|---|
Pressure reference | Gauge / Absolute |
Pressure range | -100~100 kPa,-100~1000 kPa,0~100 kPa (abs) |
Power | 10.8~30 VDC |
Output | 2 switch output (NPN/PNP open collector) and 1~5 VDC analog output |
Pressure port | R 1/4,G 3/8,G 1/4,9/16-18UNF |
Accuracy | Analog output: ± 3 %FS,Switch output: ± 3 %FS |
Display | Full 3-digit LED |
Ingress Protection | IEC IP65 |
Approval | UL recognized,CE marking applicable |
Setting method | Click the YouTube button on the left.Please see the easy-to-understand setting operation procedure in the video. |
- Documents
Series:Pressure gauge PG-35H
Pressure medium | Corrosive gases/liquids compatible with SUS316L |
---|---|
Pressure reference | Gauge |
Pressure range | -0.1~10 MPa,-0.1~35 MPa |
Power | 10.8~30 VDC |
Output | 2 switch output (NPN/PNP open collector) and 1~5 VDC analog output |
Pressure port | R 1/4,G 3/8 |
Type of mounting | Stem mount, Back mount |
Accuracy | Analog output: ± 3 %FS,Switch output: ± 3 %FS |
Display | Full 3-digit LED |
Ingress Protection | IEC IP65 |
Approval | UL recognized |
Setting method | Click the YouTube button on the left.Please see the easy-to-understand setting operation procedure in the video. |
- Documents
Series:Pressure gauge for high vacuum PG-35L
Pressure medium | Corrosive gases/liquids compatible with SUS316L |
---|---|
Pressure reference | Gauge |
Pressure range | -100~100 kPa,-100~1000 kPa |
Power | 10.8~30 VDC |
Output | 2 switch output (NPN/PNP open collector) and 1~5 VDC analog output |
Pressure port | R 1/4,G 1/4,9/16-18UNF |
Accuracy | Analog output: ± 3 %FS,Switch output: ± 3 %FS |
Display | Full 3-digit LED |
Ingress Protection | IEC IP65 |
Approval | UL recognized,CE marking applicable |
Setting method | Click the YouTube button on the left. Please see the easy-to-understand setting operation procedure in the video. |
- Documents
Series:Pressure gauge PG-75
Pressure medium | Crosive gases and Liquids compatible with SUS304 or SUS316L |
---|---|
Pressure reference | Gauge (Compound) |
Pressure range | 0~100, -100~100 kPa,0~1, -0.1~1, 0~3.5, -0.1~3.5 MPa |
Power | 10.8 ~ 30 VDC |
Output | NPN/PNP open collector output 2 and 1 ~ 5 VDC / 4~ 20 mA |
Pressure port | R 1/8,R 1/4 |
- Documents
Series:Pressure gauge PG-200
Pressure medium | Non-corrosive gases |
---|---|
Pressure reference | Gauge / Absolute |
Pressure range | 0 ~ 10 kPa,0 ~ 100 kPa,0 ~ 1000 kPa,-100 ~ 0 kPa,0 ~ 100 kPa (abs) |
Power | Lithium battery 3.6 VDC/5 ~ 10 VDC or 10 ~ 24 VDC |
Output | NPN open collector output 2 and 0 ~ 1 VDC |
Pressure port | R 1/4,M5 female |
- Documents
Series:Pressure gauge PG-208
Pressure medium | Corrosive gases/liquids compatible with SUS316L or SUS316 |
---|---|
Pressure reference | Gauge |
Pressure range | 0 ~ 100 kPa,0 ~ 1000 kPa,-100 ~ 0 kPa |
Power | Lithium battery 3.6 VDC/5 ~ 10 VDC or 10 ~ 24 VDC |
Output | NPN open collector output 2 and 0 ~ 1 VDC |
Pressure port | G 3/8 |
- Documents
Series:Handheld digital manometer PG-100N
Pressure medium | Non-corrosive gases |
---|---|
Pressure reference | Gauge (Compound) |
Pressure range | -10~10kPa, -100~100 kPa, -100~1000 kPa |
Power | AAA dry battery DC 1.5 V × 2 |
Output | 3 1/2 digit LCD display |
Pressure port | M5 female screw |
Accessories | Half union, Barb fitting, AAA batteries, strap |
Series:Handheld digital manometer PG-100B
Pressure medium | Gases / liquids compatible with SUS316L |
---|---|
Pressure reference | Gauge/Absolute |
Pressure range | -100~100, -100~1000 kPa, 0~100 kPa abs |
Power | AAA dry battery DC 1.5 V × 2 |
Output | 3 1/2 digit LCD display |
Pressure port | M5 female screw |
Accessories | One touch fitting, Insert ring, strap, AAA batteries, Protectiv cover |
Series:Handheld digital manometer PG-100《EOL》
EOL Information |
This series was discontinued.The recommended substitutes are the following new 2 series.
Calibration/Repair services and battery changes are still available until November 2028.
|
---|
- ※
- Click the “Product details” to see the cross reference with the recommended successors.
- ●To buy this product, please contact Sales Reps, Distributors.
Series:Pressure indicator PZ-30
Input signal | 1~5 V (V) / 4~20 mA (I) |
---|---|
Input impedance | 10 kΩ (V) /250 Ω (I) |
Supply voltage | 10.8~30 V DC |
Output status | NPN/PNP 2-point open collector output |
Analog output | 1~5 VDC (Voltage output) / 4~20 mA (Current output) |
Display accuracy | ± 0.2 (±1 counts) |
- Documents
Series:Pressure indicator PZ-200
Input signal | 1~5 V (V) / 4~20 mA (I) |
---|---|
Input impedance | Approx. 120 kΩ (V) / 51 Ω (I) |
Supply voltage | 12~24 V DC |
Output status | NPN 4-point Open collector output |
Analog output | 4~20 mA (Current output) |
Display accuracy | ± 0.1 (±2 counts) |
- Documents
Series:Notes to Pressure Sensors/Switches
Click on the following, you can download the PDF. | |
Note.1 | Prior to placing a purchase order / Warranty |
Note.2 | Outline |
Note.3 | Operating Principles |
Note.4 | Applications |
Note.5 | Handling notes |
Note.6 | Glossary |
Note.7 | Pressure Sensors Recommended External Circuit |
Note.8 | Pressure Switches Typical Circuit Connection |
- Documents
- ●To buy this product, please contact Sales Reps, Distributors.
Series:Pressure Sensors and Liquid Leak Sensors FAQ
1. About Products |
Q20. How to solve Zero Point ERRORs in pressure gauges
|
---|---|
2. Documents and Certificates | |
3. Maintenance and Calibration |
- ●To buy this product, please contact Sales Reps, Distributors.
Series:Pressure Sensor Obsolete Products
Obsolete Model | Time of Discontinuation | Recommended Replacement |
---|---|---|
Pressure Gauge PG-300 |
Dec., 2004 | PG-35 / PG-35H |
Pressure Sensor (with Amp.) PA-300 |
Sep., 2005 | PS40 |
Pressure Switch PS3 |
Nov., 2006 | PS40 |
Pressure Sensor (with Amp.) PA-850-VC |
Nov., 2006 | PA-830 |
Pressure Sensor (with Amp.) PA-858-VC |
Nov., 2006 | PA-838 |
Pressure Switch PS85-VC |
Nov., 2006 | PS83 |
Pressure Sensor (Module) P-8100 |
Jul., 2013 | P-8505 |
Pressure Sensor (with Amp.) PA-808 |
Feb., 2015 | PA-858 |
Pressure Switch PSA4 / PS10 |
Feb., 2015 | PS6 / PS60 |
Pressure Switch PS7 |
Feb., 2015 | PA-850 / PG-75 |
Pressure Sensor (with Amp.) PA-960 |
Oct.,2019 | PA-970S / |
Pressure Sensor (with Amp.) PA-968 |
Oct.,2019 | PA-978S |
Pressure Switch PS4 |
Jul., 2021 | PS40 / PS6 |
Pressure Switch PS5 |
Jul., 2021 | PS83 / PS85 |
Pressure Switch PS87 |
Feb., 2022 | PS86 / PS97 |
Pressure Sensor (with Amp.) PA-870 |
Feb., 2022 | PA-750 / PA-860 / PA-970S |
Pressure Sensor (with Amp.) PA-878 |
Feb., 2022 | PA-758 / PA-868 / PA-978S |
Pressure Sensor (with Amp.) PA-708 |
Mar., 2022 | ― |
Handheld digital manometer PG-100 |
Nov., 2022
Nov., 2022 (Calibration services : until the end of November 2028.) |
PG-100N, PG-100B (for liquid) |
- Documents
- ●To buy this product, please contact Sales Reps, Distributors.
Series:Quick reference table with filter search
- Recommended for checking the product lineup and narrowing down the products according to your desired specifications. Click the button below to proceed.
- Documents
- ●To buy this product, please contact Sales Reps, Distributors.
Series:Pressure sensors special feature
Chapter 1 | What is a pressure sensor? |
---|---|
Chapter 2 | Introduction of our pressure sensors |
Chapter 3 | Strengths of our pressure sensor |