Rotary encoders RE12D
Achieves 2-phase rectangular wave output with φ12 mm
- φ12 mm, 2 phases square wave
- High resolution 100 to 300 P/R
- Low torque, low inertia
- Cost effective ORoHS compliant
PART NUMBER DESIGNATION
RE12D- | 100- | 2 | 0 | 1- | 1 |
---|---|---|---|---|---|
Series name |
Resolution (P/R) 100, 200, 300 |
Output phase 2:“A” & “B” |
Output phase “Z” 0:Non |
Rectangle shaping AMP&Input voltage 1:5 V |
Output connection 1:Cable wire |
LIST OF PART NUMBERS
Part number | Resolution |
---|---|
RE12D-100-201-1 | 100 (P/R) |
RE12D-200-201-1 | 200 (P/R) |
RE12D-300-201-1 | 300 (P/R) |
ELECTRICAL CHARACTERISTICS
Input voltage | DC5 V ± 5 % |
---|---|
Input current | 50 mA maximum |
Output wave form | Square ware |
Output phases | A, B |
Resolution (P/R) | 100, 200, 300 |
Phase difference of A & B outputs | 90° ± 45° |
Maximum frequencies response | 10 kHz |
Output signal | “1 (High)”:+ 4.5 V minimum “0 (Low)”:+ 0.5 V maximum |
Output impedance |
1 kΩ |
Light source |
LED |
MECHANICAL CHARACTERISTICS
Starting torque | 0.05 mN·m {0.5 gf·cm} maximum |
---|---|
Inertia | 0.01 g·cm2 |
Shaft loading (When mounting) |
Radial,Axial:1.96 N {200 gf} maximum |
Net weight | 10 g |
Environmental characteristics
Operating temp. range | 0~50 °C |
---|---|
Storage temp. range | -20~80 °C |
Protection grade | IP40 |
RELIABILITY TEST
Test item | Test conditions | ||
---|---|---|---|
Vibration | Power OFF | Amplitude : 1.52 mm or 98.1 m/s2 (10G) whichever is smaller. 10~500Hz excursion 5 min/cycle, 1 hour each for X, Y, Z, directions. |
|
Shock | Power OFF | 1 time each in 6 directions (X, Y, Z) at 490 m/s2(50 G), 11 ms. | |
High temperature exposure | Power OFF | 80 °C 96h | (To be measured after leaving samples for 1h at normal temperature and humidity after the test.) |
Power ON | 50 °C 96h | ||
Low temperature exposure | Power OFF | -20 °C 96h | |
Power ON | 0 °C 96h | ||
Humidity | Power OFF | 40 °C Relative humidity 90〜95 % 96 h (To be measured after wiping out moisture and leaving samples for 1h at normal temperature and humidity after the test.) |
|
Thermal shock | Power OFF | To be done 5 cycles with the following condition (To be measured after leaving samples for 1 h at normal temperature and humidity after the test.) 70 °C 0.5 h、-20 °C 0.5 h |
OUTPUT
OUTPUT CIRCUIT
OUTLINE DIMENSIONS
Documents
- ●The above contents and descriptions are subject to change without notice.