NIDEC COMPONENTS logo
NIDEC COMPONENTS logo

LIST

×

×


Products

Distributor

US-English

×

Micro Blowers: TF037C-2100-F

●To buy this product, please go to the following Online Web stores.
To the Micro blower TF all series page on the DigiKey online shop
To the Micro blower TF all series page on the Mouser online shop
To the Micro blower TF all series page on the Newark online shop
To the Micro blower TF037 series page on the RS online shop

Micro Blower TF037C-2100-F

 

FeaturesFeatures
  • Aerodynamic bearings

  • Compact / Light weight

  • High static pressures

  • Low vibration

  • Long life due to aerodynamic bearings without heat dependence

  • Two type available with or without Fixing Leg

  • Resin in full compliance with UL94 V0

STANDARD SPECIFICATIONS

No.ItemTF037C-2100-FRemarks
1 Operating Voltage Range 10~30 V  
2 Direction of Rotation CCW(Counterclockwise viewing from the air vent side)  
3 Kind of Gas Normal Air Do not use to any corrosive gas.
4 Type of Motor 3 phase 8 pole Brushless
(Y Connection)
 
5 Number of Poles 8 Poles (4 pole pairs)  
6 Bearing Type Aero Dynamic Bearing  
7 Recommended Mounting Position Axis Vertical
(Plate Downward)
Avoid vibration and shock while the product is operating. It may damage product.
8 Maximum Input Coil Current 3.0 A Max. In case, the rotor is lock up, the coil may be destroyed by surge current.
The protection circuit to prevent surge current must be installed for safety.
9 Power Supply Current 0.9 A Max. at 3.0 kPa 100 L/min
Temp.:23±5℃,
Humidity:45~85%RH,
Air Pressure:101.3 kPa 
10 Power Consumption 21.6 W Max.
11 Minimum Flowrate 5 L/min  
12 Torque Constant 0.0025 N·m/A  
13 Rotation Speed Range 6,000~45,000 rpm Rotation Speed = Hole Sensor Frequency×15 
14 Acoustic Audible Noise 65 dB(A)
at 3.0 kPa 100 L/min
Temp.:23±5℃,
Humidity:45~85%RH,
Air Pressure:101.3 kPa 
Measured 1 m away from the intake vent (Including dark noise as 15 dB)
15 Coil Resistance 0.5 Ω at 20℃ (Between 2 phase)
16 Coil Inductance 20 μH at 20℃、10 kHz (Between 2 phase)
17 Insulation Pressure Resistance E grade (JIS C 4003 Cable for Coil)  
18 Insulation Resistance 20 MΩ Min. between Coil terminal and Plate at 500V DC(JIS C 4003)  
19 Insulation Pressure Resistance Leak Current:1mA Max. At min 600 VAC between coil terminal and plate more than one second
20 Fixing Leg With  
21 Weight 94 g Reference value
20 Rotor Inertia 2.1×10-6 kg・m2  
23 Operating Temperature And Humidity -10~60°C, 10~95%RH Condensation may cause damage to product.
24 Storage Temperature Humidity range -20~60°C, 10~95%RH Condensation may cause damage to product.
25 Operating Ambient Pressure 770~1,060 hPa  

OPERATING RANGE IN P-Q & Q-I RATING

  • P-Q and Q-I conditions must not exceed the ratings listed below.
  • The general purpose driver TF037E-1000-D is setup to the configuration for general use. In using the general purpose driver, the output may not reach the maximum ratings listed below.
  • P-Q and Q-I characteristics are for reference purpose only. The driver must be configured properly by measuring the actual condition before use.

*The characteristics below are measured with our companyʼs driver at axis vertical position.
*Ambient Temperature:25°C,Barometric Pressure: 101.3 kPa

⦿ Characteristics at 24 V P-Q/Q-I
⦿ Characteristics at 12 V P-Q/Q-I

INTERFACE

⦿ CONNECTOR

J.S.T.MFG.CO.,JTD SM12B-PASS

⦿ TERMINAL ARRAY
Pin No.SymbolContent
Vcc Power for Hall Sensor
H2- Output of Hall 2
H2+
H3- Output of Hall 3
H3+
H1- Output of Hall 1
H1+
GND GND
TH Thermistor
V Coil (V)
W Coil (W)
U Coil (U)
⦿ HARNESS SIDE
J.S.T.MFG.CO.,JTD SM12B-PASS SM12B-PASS
Pressure Welding 12PAF-6S (Retainer:PAFS-12V-S)

Crimping

PAP-12V-S (Contact:SPHD-001T-P0.5)
  • Both pressure welding and crimping are available.
  • Recommended size: AWG#22
⦿ INTERNAL CIRCUIT / LIMITING RESISTOR

  • The current into the hall sensor must be restricted within the rating listed below by using a resistor.
⦿ HALL SENSOR CHARACTERISTIC
Input Current Max 10 mA At maximum operating load at temperature 60°C
Input Resistance 250 ~ 450Ω Per one Hall sensor
Differential Output Min 300mV p-p VH=(VH+)-(VH-) at 10 mA in Input current

・Equivalent of ASAHI KASEI Electronics HW-105A

⦿ THERMISTOR CHARACTERISTIC
Reference Resistance 25°C 10kΩ
Operating Current 25°C 0.31 mA
B Constant[25/85℃] 4,100 K
Maximum Temperature 86 ℃ (Thermistor Resistance: 0.97 kΩ)
  • Equivalent of TDK NTCG164BH103JT

TIMING CHART

OUTLINE DIMENSIONS

Micro Blower Kit with driver

  • For the model with mounting brackets "TF037C-2100-F", Kits with driver and wire harness for the blower available.
  • They will help customers shorten their evaluation and product development times.
● Kit Part Number : TF037C-2100-P
List of the kit
1 Micro Blower (TF037C-2100-F)
2 Special Driver (TF037-1001-D)
3 Wire Harness (for Driver-Blower connection)
4 Wire Harness (for Driver-Power connection)

*The Drivers are sold separately as an optional item.

CONNECTION

*Connect the micro blower, driver, and harness as follows.

Precautions for handling

Do not give strong strass such as shock, vibration and oscillation to product. While product is working, such stress may cause Lock-up of rotor which can lead the product to permanent damage.
This product doesn't include a driver. Buyer has to install and configure a driver properly according to characteristic, rating and recommendation in this specification.
This specification doesn't mean that our guarantees Product will not be breakdown or out of order in any case. Buyer has to implement a proper protection measure on Buyer's system in preparation for sudden malfunction and out of control of Product.
Product characteristic was measured with our standard measuring equipment*1), therefore the characteristics in actual condition or use at Buyer may different from the characteristic in this specification. Checkout the characteristic results at the actual condition before use. *1) Flowmeter we using is a mass flowmeter of thermal method displaying volume flow rate at 20℃・1 air pressure.
Turn off the power of the product and any equipment attached to the product when putting on or taking off the cables.
Turn off the power immediately and stop using the product in the following cases.
1. In case water or foreign substances get into the product.
2. In case the product is dropped or the housing is broken.
3. In case unusual odor, abnormal noise, or smoke are generated from the product.
Do not use or store product where shock, vibration, static electricity might occurs and with high temperature, humidity, dust, corrosive gas, no ventilation and near splashing water, chemical material or oil.
Do not block the air inlet and outlet.
Please connect and don't use air inlet of this product in series.
Product has parts rotating at high speed which might cause serious personal injury. Pay attention to handle product while it works.
Please contact us if you have any questions regarding installation.

Warranty

Warranty period of the Product is one year from delivery. In case, defect has been found in the Product during the warranty period and it was found that NIDEC COMPONENTS (here in after referred as NCC) is responsible and liable for the defect, NCC shall either repair or replace the defected Product free of charge, provided, however, that foregoing warranty shall be voided and shall not be applied in any instances where.
1. Buyer fails to carry out proper handling, operating, installation, testing, service and checkout of the Product and/or to follow NCC’s instruction or advice with respect to any of these matters.
2. Buyer utilizes any attachments or interface devices or makes any modification to the product which are not approved in writing by NCC.
3. Buyer incorporates any parts not supplied by NCE into the Product and/or combines any equipment.not supplied by NCC with Product.
4. The alleged defect arises out of NCC’s compliance with any written request, instruction, design change, drawing or specification (including but not limited to instruction manual, installation manual, and service manual prepared by Buyer) specifically furnished or imposed by Buyer upon Seller.
5. Defect arisen due to reason that it has been unable to be aware of the problem by ordinary scientific and technical knowledge and capability in those days.
6. Failure or damage caused by natural disaster, fire or unavoid able factors.
In addition, NCC shall not indemnify Buyer against any damages and losses which are alleged to have arisen as a result of and/or caused by defect or malfunction of Product. Buyer must implement a proper protection measure on Buyer’s system in preparation for sudden malfunction and out of control of Product.

Disclaimer

The product is not designed for use in equipment or devices that could have an impact on life or body, or those that could damage property (These include, but are not limited to, medical equipment, disaster prevention equipment, security equipment, combustion control equipment, infrastructure control equipment, vehicle equipment, transportation equipment, on-board equipment, aviation equipment, space equipment, and nuclearrelated equipment). If you want to use this product for any of the above-mentioned equipment or devices, be sure to contact our point of contact beforehand. The details of warrant y shall be as per the descriptions in this document and we shall not be liable for any damage on you resulting from the use of any equipment or device (including control systems) which is not in accordance with this document (hereinafter referred to as "use in violation"). In the case where you resell our products, we shall not be liable for any damage on a third party resulting from use in violation by the third party, and even if we make payment to the third party in connection with such use in violation regardless of the name by which such payment may be called, we may demand the whole amount thereof from you.
This product is strictly prohibited from using, providing or exporting for the purposes of the development of weapons of mass destruction or military use. We are not liable for any losses, damages, claims or demands caused by any provision or export to the person or entity who intends to develop, manufacture, use or store nuclear, biological or chemical weapons or missiles, or use any other military purposes.
All the information described herein(product data, specifications, figures, tables, programs and application circuit examples, etc) is current as of publishing date of this document and is subject to change without notice.
This specification doesn’t mean that NCC guarantees Product will not be breakdown, out of order and fail in any case. Buyer has to therefore take responsibility to give thorough consideration to safety design to prevent accidents causing injury or damage that may ensue from the Product’s failure or malfunction. The entire system in which the Product is used must be sufficiently evaluated and judged whether the Product operates without problems. We are not liable for losses, damages, claims or demands which are claimed to have arisen as a result of and caused directly or indirectly by Product’s defect, out of order, failure and malfunction.
●The above contents and descriptions are subject to change without notice. 

Products

×

page top