US-English

×

Inclinometers ESC3000Z

  • ESC3000Z
    ESC3000Z
  • ESC3000Z
    ESC3000Z

Contact Us

●To buy this product, please contact Sales Reps, Distributors.

Drip-proof, High Accuracy , User-friendly Functons Tilt Angle Sensors

 

FeaturesFeatures
  • ESC-Series industrial inclinometers are high performance sensors used MEMS accelerometer to determine inclination in X and Y axes with excellent precision.
  • Using Aluminum Die-Cast housing, the versions offer mechanical stability andencapsulated sensor, and in addition a high environmental protection in harsh industrialenvironments.
  • Dual Axis Measurement : up to ±80°
  • High accuracy : Absolute Linearity < ±0.5%FS
  • Various Data Output : Voltage, Current, Serial RS-485
    *Requesting other serial interface such as SAE J1939 & CANopen, please contact us.
  • Stable measurement under vibration
  • Programmable Parameters : Inclination range, Baud Rate, Data Transmissions Period, Filter factor

Standard Specifications

Output typeVoltage RatioVoltageCurrentSerial(RS-485)
Electrical Angle ±10°, ±20°, ±30°, ±45°, ±60°, ±80°
Separate choice of X and Y axes (Option)
Angle resetting function by RS-485 command is available (Option)
±80°
Absolute Linearity ± 0.5 %FS ±0.1° (~ ±10°)
±0.2° (~ ±30°)
±0.5° (~ ±80°)
Input Voltage 5±0.25 VDC 8 ∼ 30 VDC 24±4 VDC
Current Consumption 75 mA max.
Output Range 10 ~ 90 %Vin 0.5 ~ 4.5 V 4 ∼ 20mA
Output Resolution 12bit equivalent
Damper control Time constant against input step : 443ms (Standard)
Selectable 16 steps during 70ms∼900ms (Option)
Damper resetting function by RS-485 command is available (Option)
Temp.Characteristics 0 ° position:± 0.5° (- 30 ~ 85 ℃ deviaton from 25 ℃)
Net Weight Approx. 300 g 
Cable 6 cores Cabtyre Cable, Outer diameter: dia. 7.4 mm, Core: 0.5 mm
EMS ISO11452 corresponding 1 % output shifting at 10 MHz∼1 GHz
100 V/m (Ratio, Current, Serial) , 50 V/m (Voltage)
EMI CISPR25 3rd.edit CLASS1
Operational Temp.Range -30 ~ 85 ℃
ESD ± 12 kV
Vibration 70 m/s, 5 ~ 200 Hz / 10 min. 2 hours 
Shock 1000 m/s,  Half sine wave 6 ms
IP Grade IP67
Index Point Teach-in Index point ( ± 5° max. / horizonality) Teach-in setting. (Option)
◆Temperature Characteristics
By our unique technology. ESC3000Z series is individually conpensented temperature characteristics each unit. ESC3000Z series realized stable temperature characteristics.

Part Number Designation

ESC30-10Z-R-DB0L00

Series Number

X axis
analog output angle

10 : ±10°

20 : ±20°

30 : ±30°

45 : ±45°

60 : ±60°

80 : ±80°

Output axis

Z : X&Y
(Standard)

X : X axis only

Y : Y axis only

Output type

R : Ratio 10 ~ 90 %Vin

V : Voltage 0.5 ~ 4.5 V

A : Current  4 ~ 20 mA

D : RS 485 only

Dampar control  

※See table below

Output Characteristics

0 : X&Y Output increasing
(Standard)

1 : Output decreasing

     Y Output increasing

2 : Output increasing

     Y Output decreasing

3 : Output decreasing

     Y Output decreasing

Baud rate

L : 9600bps
(Standard)
H : 115200 bps

Terminating resistance

0 : Not avail.
(Standard)
1 : Available

USAC

0 : Not avail.
(Standard)
1 : Available

  • Cut-off Frequency and Time constant against Damper time constant are shown the below table. It is possible to choose the best Damper time constant by operating speed and vibration condition.
Part NumberLevelCut-off FrequencyTime constant
D0 0 11.2 Hz

120 ms

D1 1 9.27 Hz 150 ms
D2 2 7.65 Hz 160 ms
D3 3 6.32 Hz 170 ms
D4 4 5.21 Hz 190 ms
D5 5 4.30 Hz 220 ms
D6 6 3.55 Hz 250 ms
D7 7 2.93 Hz 290 ms
D8 8 2.42 Hz 330 ms
D9 9 2.00 Hz 360 ms
DA 10 1.65 Hz 420 ms
DB 11 1.36 Hz 500 ms (Standard)
DC 12  1.21 Hz 590 ms
DD 13 0.92 Hz 700 ms
DE 14 0.76 Hz 810 ms
DF 15 0.62 Hz 970 ms

New User New User-Friendly Functions

Easy Resetting Function for Index Point(0°)

  • Only 5 seconds to reset index point (0°) using User-Settable Adjustment Card. (USAC)
    (1) Please touch ESC 3 times with USAC.
    (2) Then current position (±5°max./horizontality) will be changed to index point.
  • Any electrical connections do not needed.
  • *Note: USAC is optional item

Programmable Digital Damping Control Function

  • ESC3000Z serues implements the digital filter that would remove external noise to give the user a choice of certain filter factor from 16 available settings.
  • Existing inclinometers have to be add extra electrical lowpass filter or mechanical damping structure.
  • ESC30xxZ apply digital filter. It makes wider choice of cutoff frequency and easy to design frequency response.
  • *Note: Frequency response is set before shipping. Programmable function will be option.

Serial communication Function

This series has RS485 interface as standard function.
Using RS-485 serial interface command, the following functions will be able to be used.
1. Retrieving of electrical angle position.
2. Retrieving of Serial number.
3. Teach-in setting of index (0°) point. (Option)
4. Changing of elecreial analog angle range. (Option)
5. Changing damper seting. (Option)
6. Changing baud rate. (Option)
7. Changing output cycle of serial data. (Option)

Output Characteristics

Schematic

Outline Dimensions

(Unit:mm)

 Tilt angle direction

Handling Instruction

  • Hall-IC sensor is impossible to measure resistance value as a variable resistor.
  • Use this sensor in the place where is protected from ESD.
  • Under acceleration 12m/s2 or Vibration Min.3000Hz, angle may not measured accurately.
  • In certain temperature environment, output at 0° may be shifed by aging effect.