Druckschalter PS86
- ●Um einen Kauf zu tätigen, wenden Sie sich an die Verteiler
oder nutzen Sie den stehenden Online-Shops unten.
Verkaufskanal Überprüfen Sie die Verteiler.- VERKAUFSKANALKlicken Sie hier, um den Verteiler zu überprüfen.
Pressure switch PS86
- Solidstate pressure switch with no mechanical moving parts
- Isolated output via a photo-coupler
- Switching pressure adjustable and hysteresis band adjustable
- Resistant against surge pressure
- SUS 316L welded stainless steel diaphragm
General specifications
- Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 V DC.
Item | 503P | 104P | 204P | 354P |
---|---|---|---|---|
Pressure reference | Gauge ※ 1 | |||
Rated pressure range | 5MPa | 10MPa | 20MPa | 35MPa |
Maximum pressure | 10MPa | 20MPa | 40MPa | 52.5MPa |
Operating temp. range | −10 ~ 75°C | |||
Compensated temp. range | 0 ~ 50°C | |||
Operating humidity | 35 ~ 85%RH(No condensation) | |||
Storage temp. | − 20 ~ 90°C(Atmospheric pressure, humidity 65 %RH maximum) | |||
Pressure medium | Hydraulic oil ※ 2 | |||
Insulation resistance | 100 MΩ min.(500 V DC) | |||
Dielectric strength | 350 V AC, 60 s(Leakage current 0.5 mA maximum) | |||
Pressure port | R 1/4、G 3/8 | |||
Net weight | Approx. 170g | |||
Protection grade | Without drip-proof cover:IP-54, With drip-proof cover:IP-65 | |||
Supply voltage | 12 ~ 24 V ± 10 % | |||
Consumption current | 15 mA maximum |
- ※ 1 The transducer measures gauge pressure using an absolute pressure sensing element.
- ※ 2 Hydraulic oil is used as a measurement medium at the time of delivery inspection.
Switch output
- Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 V DC.
No. of outputs | 1 |
---|---|
Output interface | Open collector output which insulated a photo-coupler |
Setting method | Adjustable by VR |
Adjustable range | 5 ~ 105 % of rated pressure range |
Display | Red LED ON |
Accuracy 0 ~ 50 °C (Reference temp.: 25 °C) |
± 3 %F.S. |
Hysteresis | Approx. 1 ~ 10 % of setting range |
Switching capacity | 35 V DC 100 mA |
Residual voltage | 1.2V maximum |
Response | Approx. 20ms |
ENVIRONMENTAL CHARACTERISTICS
Test item | Test conditions (At 25 ± 5 °C) | Permissible change |
---|---|---|
Vibration | 10 ~ 500 Hz, 1.5 mm maximum/98.1 m/s2 , 3 directions for 2 hours each | Switch output setting: ± 3 %F.S. maximum |
Shock | 490 m/s2 , 3 directions for 3 times each | |
Moisture resistance | 40 °C, 90 ~ 95 %RH, 240 hrs | |
Pressure cycling | 0 ~ Rated pressure, 106 cycles |
MODEL NUMBER DESIGNATION
PS86- | 503 | P- | B - | R2 |
---|---|---|---|---|
Series name |
Rated pressure range 503:0 ~ 5 MPa 104:0 ~ 10 MPa 204:0 ~ 20 MPa 354:0 ~ 35 MPa |
Pressure unit P:Pa pressure unit |
Drip-proof cover B:Non-provided H:Provided |
Fitting R2:R 1/4 G3:G 3/8 |
- ※ Please refer to the LIST OF MODEL NUMBERS when placing orders.
- ※ Hastelloy® is a resistered trade name of Haynes International Inc.
LIST OF MODEL NUMBERS
Model number | Pressure medium | Pressure reference | Fitting | Rated pressure | CAD |
---|---|---|---|---|---|
PS86-503P-B-R2 | Hydraulic | Gauge | R2 (R 1/4) | 0 ~ 5MPa | |
PS86-503P-H-R2 | Hydraulic | Gauge | R2 (R 1/4) | 0 ~ 5MPa | |
PS86-503P-B-G3 | Hydraulic | Gauge | G3 (G 3/8) | 0 ~ 5MPa | |
PS86-503P-H-G3 | Hydraulic | Gauge | G3 (G 3/8) | 0 ~ 5MPa | |
PS86-104P-B-R2 | Hydraulic | Gauge | R2 (R 1/4) | 0 ~ 10MPa | |
PS86-104P-H-R2 | Hydraulic | Gauge | R2 (R 1/4) | 0 ~ 10MPa | |
PS86-104P-B-G3 | Hydraulic | Gauge | G3 (G 3/8) | 0 ~ 10MPa | |
PS86-104P-H-G3 | Hydraulic | Gauge | G3 (G 3/8) | 0 ~ 10MPa | |
PS86-204P-B-R2 | Hydraulic | Gauge | R2 (R 1/4) | 0 ~ 20MPa | |
PS86-204P-H-R2 | Hydraulic | Gauge | R2 (R 1/4) | 0 ~ 20MPa | |
PS86-204P-B-G3 | Hydraulic | Gauge | G3 (G 3/8) | 0 ~ 20MPa | |
PS86-204P-H-G3 | Hydraulic | Gauge | G3 (G 3/8) | 0 ~ 20MPa | |
PS86-354P-B-R2 | Hydraulic | Gauge | R2 (R 1/4) | 0 ~ 35MPa | |
PS86-354P-H-R2 | Hydraulic | Gauge | R2 (R 1/4) | 0 ~ 35MPa | |
PS86-354P-B-G3 | Hydraulic | Gauge | G3 (G 3/8) | 0 ~ 35MPa | |
PS86-354P-H-G3 | Hydraulic | Gauge | G3 (G 3/8) | 0 ~ 35MPa |
INTERNAL ELECTRICAL SCHEMATICS
SWITCH OUTPUT SCHEMATICS
OUTLINE DIMENSIONS
Unterlagen