NIDEC COMPONENTS logo
NIDEC COMPONENTS logo

Liste

×

×


Produkte

Verteiler

EU-Deutsch

×

Druckmessgerät PG-35L

●Um einen Kauf zu tätigen, wenden Sie sich an die Verteiler
oder nutzen Sie den stehenden Online-Shops unten.
Verkaufskanal  Überprüfen Sie die Verteiler.
VERKAUFSKANALKlicken Sie hier, um den Verteiler zu überprüfen.
Gehen Sie zum DigiKey Online-Shop.
Gehen Sie zum MOUSER Online-Shop.

Pressure gauge PG-35L

  • For high vacuum pressure
  • For corrosive gases and liquids compatible with SUS316L stainless steel diaphragm
  • Compact • Light weight • Drip-proof structure (30 mm sq • 200 g • IP65)
  • Low consumption by nondisplay mode
  • Set data protection by panel lock function

General specifications

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 VDC.
 Model number102R103R
Pressure reference Gauge
Pressure medium Corrosive gases/liquids compatible with SUS 316L
Rated pressure range -100~100 kPa -100~1000kPa
Maximum pressure 200kPa 1500kPa
Break-down pressure 300 kPa 2000kPa
Operating temp. range -10~50°C
Compensated temp. range 0~50°C
Operating humidity 35~85%RH(No condensation)
Protection grade IP65
Type of mounting Stem mount, Back mount
Pressure Port R 1/4, G 1/4, VC (9/16 - 18 UNF)
Material of pressure port attachment SUS 316L
Net weight Approx. 150g(Including 2 m cable)
Thermal error ± 3 %F.S. (0~50 °C)
Insulation resistance 50 MΩ minimum
Dielectric strength 125 V DC 1 minute
Vacuum working pressure 1.4×10-4 Pa abs minimum
Input voltage 10.8~30 VDC(Including ripple percentage)
Consumption current 50mA maximum

Display

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 VDC.
Model number102R103R
Display element Full 3-digit LED
Rated display range −99.9~99.9kPa −100~999kPa
Multiplier settings Max. 11 settings
Display cycle Approx. 4 times/s
Negative pressure display “–” LED is ON
Display accuracy ± 1 %

Switch output

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 VDC.
Output status NPN/PNP 2-point output (Transistor, Open collector output)
Output mode Separate mode / window comparator mode
Switching capacity 30 V DC 100 mA maximum
Residual voltage 1.2 V maximum (NPN), 2.2 V maximum (PNP)
State indication Output 1 (Green LED),Output 2 (Red LED) Lighted when output is ON.
Switch hysteresis 0 ~ 300 counts(Adjustable)
Repeatability ± 0.2 %F.S. ± 1 count
Response Approx. 5, 25, 250, 2500 ms Adjustable

Analog output

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 VDC.
Output mode 3 modes
Output voltage
V zero : Pin=0,
V span : Pin=0 〜Pin (H)
1 ~ 5 V (G/V mode ZERO : 1 ± 0.2 V, SPAN : 4 ± 0.2 V
            R mode ZERO : 3 ± 0.2 V, SPAN : 2 ± 0.2 V )
103 R (R mode) ZERO : 1.36 ± 0.2 V SPAN : 3.64 ± 0.2 V
Impedance 10 kΩ
Resolution 1/204(Approx. 4.9mV/ Approx.0.123% F.S.)

ENVIRONMENTAL CHARACTERISTICS

Test itemTest conditionsPermissible change
Vibration 10 ~ 500 Hz, 98.1 m/s2 or 1.5 mm P-P,
3 directions for 2 hours each
Amount of analog output fluctuation is permitted
by adding conversion error of 20 mV. ※ 1
   
Shock 490 m/s2 , 3 directions for 3 times each
Moisture resistance 40 °C, 90 ~ 95 %RH, 240 hrs
Pressure cycling 0 ~ Rated pressure, 106 cycles

※ 1Change in the pressure indication, switch operating points and analog output.

MODEL NUMBER DESIGNATION

PG - 35L-102R-NVCB

Series name

Pressure range

102:-100~100 kPa

103:-100~1000 kPa

Pressure reference 

R:Compound pressure

   (Negative pressure~Positive pressure)

Switch output interface

N:NPN open collector

P:PNP open collector

Fitting

R:1/4

G2:G 1/4

VC:9/16 - 18 UNF (Gusket joint)

Port

Blank:Stem mount

B:Back mount

LIST OF MODEL NUMBERS

Model numberRated pressure rangePressure referenceFittingPort FSwitch output interfaceCAD
PG-35L-102R-NR2 −100~100 kPa Gauge R2 (R 1/4) Stem mount NPN
➡PG-35L-102R-PR2 −100~100 kPa Gauge R2 (R 1/4) Stem mount PNP
PG-35L-103R-NR2 −100~1000 kPa Gauge R2 (R 1/4) Stem mount NPN
➡ PG-35L-103R-PR2 −100~1000 kPa Gauge R2 (R 1/4) Stem mount PNP
 PG-35L-102R-NG2 −100~100 kPa Gauge G2 (G 1/4) Stem mount NPN
➡PG-35L-102R-PG2 −100~100 kPa Gauge G2 (G 1/4) Stem mount PNP
PG-35L-103R-NG2 −100~1000 kPa Gauge G2 (G 1/4) Stem mount NPN
➡PG-35L-103R-PG2 −100~1000 kPa Gauge G2 (G 1/4) Stem mount PNP
PG-35L-102R-NVC −100~100 kPa Gauge VC (9/16-18 UNF) Stem mount NPN
➡PG-35L-102R-PVC −100~100 kPa Gauge VC (9/16-18 UNF) Stem mount PNP
PG-35L-103R-NVC −100~1000 kPa Gauge VC (9/16-18 UNF) Stem mount NPN
➡PG-35L-103R-PVC −100~1000 kPa Gauge VC (9/16-18 UNF) Stem mount PNP
PG-35L-102R-NR2B −100~100 kPa Gauge R2 (R 1/4) Back mount NPN
➡PG-35L-102R-PR2B −100~100 kPa Gauge R2 (R 1/4) Back mount PNP
PG-35L-103R-NR2B −100~1000 kPa Gauge R2 (R 1/4) Back mount NPN
➡ PG-35L-103R-PR2B −100~1000 kPa Gauge R2 (R 1/4) Back mount PNP
 PG-35L-102R-NG2B −100~100 kPa Gauge G2 (G 1/4) Back mount NPN
➡PG-35L-102R-PG2B −100~100 kPa Gauge G2 (G 1/4) Back mount PNP
PG-35L-103R-NG2B −100~1000 kPa Gauge G2 (G 1/4) Back mount NPN
➡PG-35L-103R-PG2B −100~1000 kPa Gauge G2 (G 1/4) Back mount PNP
PG-35L-102R-NVCB −100~100 kPa Gauge VC (9/16-18 UNF) Back mount NPN
➡PG-35L-102R-PVCB −100~100 kPa Gauge VC (9/16-18 UNF) Back mount PNP
PG-35L-103R-NVCB −100~1000 kPa Gauge VC (9/16-18 UNF) Back mount NPN
➡PG-35L-103R-PVCB −100~1000 kPa Gauge VC (9/16-18 UNF) Back mount PNP

Marked ➡ is manufactured upon receipt of order basis.

INTERNAL ELECTRICAL SCHEMATICS

SELECTION OF DISPLAY MULTIPLIER

  • The last digit/letter represents the selection code : Blinking red LED indicates negative pressure.

  • Diagonal column: Display multiplier cannot be selected due to resolution and number of digits.
  • (Selection code is not indicated either.) Selection code is set at “A” prior to shipment.

ANALOG OUTPUT MODE

  • Selection code is set at “G” prior to shipment

SWITCH OUTPUT MODE

  • Note 1. In the Separate Mode, setting 1 corresponds to SW1, and Setting 2 corresponds to SW2.
  • Note 2. In the Window Comparator Mode, the minimum value for SW1 and SW2 corresponds to Setting 1 and the maximum value corresponds to Setting 2.

OUTLINE DIMENSIONS

Unless otherwise specified tolerance : ± 0.5 (Unit: mm)

 

Others

  • Tube at atmospheric pressure intake
    If there is any possibility that the sensor may become wet with oil or water, which may enter the case through the air intake, connect a silicon tube, or similar, to the intake and position the end of the tube in a suitably safe place. Be sure not to bend the tube or block the end of the tube.
  • Piping
    Use a wrench on a hexagon of fitting part. Do not hold the main body when tightening.

Customization

We also offer customized solutions. Please contact your local sales office for details.
Model numberShape and other customization
PG 35L-103R-NVC-056 Use no oil

ACCESSORIES (Sold separately)

NameSeries nameContentsApplicable model
Panel holder set ACPG-003 Panel holder cover
Panel holder
Panel stopper (2pcs.)
PG-30 · PG-35 · PG-75 ·
PG-35H · PG-35L
Holder cover set
(For protecting gauge operating panel)
ACPG-004 Panel holder cover
Panel holder
PG-30 · PG-35 · PG-75 ·
PG-35H · PG-35L

HOW TO MOUNT OPTIONAL ACCESSORIES (Sold separately)

◆PG-30 • PG-35 • PG-35H • PG-35L • PG-75 Panel cut holder set & holder cover set

 

◆Panel holder cover set

 

 

●Die oben genannten Inhalte können ohne vorherige Ankündigung geändert werden.

Produkte

×

page top