Dedicated to the Micro Blower TF029 series

  • The drivers enable users to vary the speed of the motor by adjusting the control voltage of the external input.
  • Contents of the kit are Driver board and Harness.
  • Wire Harness: for Driver-Power connection

STANDARD SPECIFICATIONS

  • Unless otherwise specified, the environmental conditions are 23°C±5°C, normal humidity, and atmospheric pressure range 90 to 106kPa
No.ItemItem
1Configuration Drivers(Dedicated to the Micro Blower TF029 series)
2Rotational Speed 36,000 r/min(reference value) at 2.0kPa, 100L/min
3Power Consumption 14.9W max. at 2.0kPa, 100L/min
4Rated Voltage DC 24 V±10%
5Max. Input Current 2.0 A max.(DC)  (Excluding inrush current)
6Readiness time 5sec max.From power on to motor start
7Running Current 0.62 A max. at 2.0kPa, 100L/min
8Weight 40 g max.
9Operating Temperature -10~ 50 °C
10Operating Humidity Range 10~ 90 %RH  (No condensation)
11Storage Temperature -20~ 60 °C
12Storage Humidity Range 10~ 90 %RH  (No condensation)
13Resistance to Vibration To meet the Spec after the following test Non-operating
  Kind of Vibration Frequency Rang
Frequency Range  10 ~ 22Hz  amplitude 1mm
22 ~ 50Hz, 19.6m/s(2G acceleration)
Sweep to-and-fro, approx. 5min.
Test Time X, Y, Z directions, 60min. each
14Resistance to Shock To meet the Spec after the following test Non-operating
  Acceleration 294m/s2(30G)
Pulse Width 6ms
Shock Waven Semi-sinusoidal wave
Number of Shock X, Y, Z, directions, once per each direction

INTERFACE

 

CN1(CONNECTOR FOR CONTROL) SPECIFICATIONS

 

POWER SUPPLY,CONTROLLER VOLTAGE INPUT

※To avoid high in rush current and protect driver, follow below chart at power up and CNT signal input sequence
  • ① Keep power rise time(10 → 90%) is more than 400us. If high rate power is applied, in rush current will be so huge.
  • ② Wait more than 100ms after power exceeds 12V to apply CNT signal.

 

PROTECTIVE FUNCTIONS

Protective FunctionsDescription
Over current If over voltage detected at power line, Blower will be stopped. Recover: Check and correct supply voltage.
Over current When power line current exceeds 3A, fuse will be opened and cut off power. Recover: Contact with us.
High temperature When high Turbo Fan internal temperature, outputs error signal and turn it off. If error is detected, LED will blink at 1Hz Recover: Wait until it's cooled down and try again. (If not solved, contact with us.)
Over speed When motor speed exceeds limit, outputs error signal and turn it off. If error is detected, LED will blink at 1Hz Recover: Reduce CNT signal voltage and try again.(If not solved, contact with us.)
Over current at motor coil When motor coil current exceeds limit, outputs error signal and turn it off. Recover: Check motor operation condition.
Abnormal voltage of supplied power When power supply voltage exceeds limit, outputs error signal and turn it off. If error is detected, LED will blink at 1Hz Recover: Check power supply voltage and try again
Abnormal operation When any failure is detected on driver, outputs error signal and turn it off. If error is detected, LED will blink at 4Hz Recover: Check power supply voltage and try again.(If not solved, contact with us)
  • Normal operation : Green LED is ON. (Red is OFF.)
  • Abnormal condition : Red LED is blinking. (Green is turned off.)

OUTLINE DIMENSIONS