Rotary encoder RE20F
- ●To make a purchase, contact Distributors, or use e-commerce below.
SALES CHANNEL ;Check our Distributors.- SALES CHANNELClick here to check our Distributors.
Compact two-phase output
- Compact, dia.: 20 mm
- Low torque, low inertia
- RoHS compliant
PART NUMBER DESIGNATION
RE20F- | 100- | 1 | 0 | 0 |
---|---|---|---|---|
Series name |
Resolution (P/R) 100, 300 |
Output phase 1:“A” only 2:“A” & “B” (100 P/R only) |
|
|
LIST OF PART NUMBERS
Part number | Output phases | Resolution |
---|---|---|
RE20F-100-100 | “A” only | 100 (P/R) |
RE20F-300-100 | “A” only | 300 (P/R) |
RE20F-100-200 | “A” & “B” | 100 (P/R) |
Electrical characteristics
Output phases | 1 phase “A” only | 2 phase “A” & “B” |
---|---|---|
Photo-sensor maximum current | 45 mA maximum (at 25 °C) | |
Output wave form | Quasi-sinusoidal | |
Output phases | A | A, B |
Resolution (P/R) | 100, 300 | 100 |
Phase difference of outputs A & B | ——— | 90° ± 45° |
Maximum frequency response | ——— | 12 kHz |
Output signal | 150 mVp-p minimum ※1 | 1 Vp-p minimum |
Output signal amplitude variation ※2 | 40 % maximum | |
Light source | LED |
※ 1 Measured at CP1 in the fig.A of ‘MEASUREMENT CIRCUIT’ on the following page.
※ 2 One phase only : Measured at CP2 in the fig.A of ‘MEASUREMENT CIRCUIT’ on the following page.
※ 2 One phase only : Measured at CP2 in the fig.A of ‘MEASUREMENT CIRCUIT’ on the following page.
Mechanical characteristics
Starting torque | 0.05 mN·m {0.5 gf·cm} maximum | ||
---|---|---|---|
Inertia | 0.2 g·cm2 maximum | ||
Shaft loading (When mounting) | Radial | 1.96 N {200 gf} maximum | |
Axial | 4.9 N {500 gf} maximum | ||
Net weight | Approx. 15 g |
Environmental characteristics
Operating temp. range | 0 ~ 50 °C |
---|---|
Storage temp. range | −20 ~ 80 °C |
Protection grade | IP40 |
RELIABILITY TEST
Test item | Test conditions | ||
---|---|---|---|
Vibration | Power OFF |
Amplitude : 1.52 mm or 98.1 m/s2 (10 G) whichever is smaller. |
|
Shock | Power OFF | 1 time each in 6 directions (X, Y, Z) at 490 m/s2 (50 G), 11 ms. | |
High temperature exposure | Power OFF | 80 °C 96 h | (To be measured after leaving samples for 1h at normal temperature and humidity after the test.) |
Power ON | 50 °C 96 h | ||
Low temperature exposure | Power OFF | -20 °C 96 h | |
Power ON | 0 °C 96 h | ||
Humidity | Power OFF | 40 °C Relative humidity 90 〜95 % 96 h (To be measured after wiping out moisture and leaving samples for 1h at normal temperature and humidity after the test.) |
|
Thermal shock | Power OFF | To be done 10 cycles with the following condition (To be measured after leaving samples for 1 h at normal temperature and humidity after the test.) 70 °C 1 h、‐20 °C 1 h |
OUTPUT
EXTERNAL SCHEMATICS
⦿ 2 phase 100 P/R
INTERNAL CIRCUIT
⦿ 1 phase 100・300 P/R
⦿ 2 phases 100 P/R
MEASUREMENT CIRCUIT
⦿ 1 phase 100・300 P/R
⦿ 2 phases 100 P/R
RATINGS
⦿ LED(at 25 °C)
Maximum current | 45 mA |
---|---|
Reverse voltage | 4 V |
Power dissipation (PD) | 75 mW |
Temp. derating of PD (25 ~ 60 °C) | −1.4 mW/°C |
⦿ Photo-sensor(at 25 °C)
Collector current | 20 mA |
---|---|
Collector to emitter voltage (forward) | 20 V |
Collector to emitter voltage (reverse) | 5 V |
Collector dissipation (PD) | 75 mW |
Temp. derating of PD(25 ~ 60 °C) | −1.0 mW/°C |
OUTLINE DIMENSIONS
Unless otherwise specified, tolerance: ± 0.4 (Unit: mm)
Documents
- ●The above contents and descriptions are subject to change without notice.