Standard specifications
Operating temp. range | −10 ~ 60°C |
---|---|
Compensated temp. range | 0 ~ 50°C |
Operating humidity | 35 ~ 85%RH(No condensation) |
Storage temp. | − 20 ~ 70°C |
Pressure medium | Non-corrosive gases |
Insulation resistance | 100MΩ min. |
Dielectric strength | 500 V AC, 60 s |
Net weight (Without cable) | Approx. 5g (PA-20- **** -U) Approx. 8g (PA-20- **** -M) |
Supply voltage | 10.8 ~ 30V DC(Including ripple percentage) |
Consumption current | 20mA max. |
Analog output
Output voltage | 1 ~ 5V |
---|---|
Output current | 1mA Max.( Load resistance : 5 kΩ minimum) |
Linearity/Hysteresis | ± 0.5%F.S. |
Thermal error (Reference temp.: 25 °C) |
± 2 %F.S.(ZERO、SPAN) |
Response | Approx.1ms |
Model Number Designation
PA-20- | 102V- | U | -3M | |
---|---|---|---|---|
Series name |
Rated pressure range 102V:0 ~ −100 kPa |
Pressure port U:Universal joint (M5 male screw) |
Cable length Blank:1.5 m |
|
List of model numbers
Model numbers | Rated pressure | Maximum pressure | Pressure port | Cable length | CAD |
---|---|---|---|---|---|
PA-20-102V-U | 0 ~ −100kPa | 200kPa | Universal joint | 1.5 m | |
PA-20-102V-U-3M | 0 ~ −100kPa | 200kPa | Universal joint | 3 m | |
PA-20-102V-M | 0 ~ −100kPa | 200kPa | 2-M5 female screw | 1.5 m | |
PA-20-102V-M-3M | 0 ~ −100kPa | 200kPa | 2-M5 female screw | 3 m | |
PA-20-302R-U | − 100 ~ 300kPa | 600kPa | Universal joint | 1.5 m | |
PA-20-302R-U-3M | − 100 ~ 300kPa | 600kPa | Universal joint | 3 m | |
PA-20-302R-M | − 100 ~ 300kPa | 600kPa | 2-M5 female screw | 1.5 m | |
PA-20-302R-M-3M | − 100 ~ 300kPa | 600kPa | 2-M5 female screw | 3 m |
※ Verify the above model numbers when placing orders.
Environment Characteristics
Test item | Test conditions | permissible change |
---|---|---|
Vibration | 10 ~ 55 Hz, 1.5 mm, 3 directions for 2 hours each | Analog output : ± 2 %F.S. maximum after test |
Shock | 1000 m/s2, 3 directions for 3 times each | |
Pressure cycling | 0 ~ Rated pressure 106 cycles | |
Moisture resistance | 40 °C, 90 ~ 95 %RH, 240 h. |