Pressure switch for high pressure range PS97
-
PS97 series (Fitting angle) -
PS97 series (Connector angle) -
PS97 - G1/4, M12 connector type (Fitting angle) -
PS97 - G1/4, M12 connector type (Connector angle) -
PS97 - R1/4, DT connector type (Fitting angle) -
PS97 - R1/4, DT connector type (Connector angle)
-
PS97 series (Fitting angle) -
PS97 series (Connector angle) -
PS97 - G1/4, M12 connector type (Fitting angle) -
PS97 - G1/4, M12 connector type (Connector angle) -
PS97 - R1/4, DT connector type (Fitting angle) -
PS97 - R1/4, DT connector type (Connector angle)
- ●To buy this product, please contact Sales Reps, Distributors.
High accuracy pressure switches for middle-high pressure
The new PS97 series thin film pressure switch boasts a wide temperature range (-40~125 °C) and high accuracy of ±1 % F.S. (at 0~80 °C) with waterproof IP67 protection structure. Furthermore, wide variety of pressure range selections from 0 to 1.0 MPa, 2.5 MPa, 5.0 MPa, 10 MPa, 25 MPa, 40 MPa, 50 MPa, 80 MPa, suitable for a wide pressure range of middle-high pressure. The main target markets are machine tools, special vehicles, injection molding machines, high-pressure washing machines, and hydraulic equipment. We confirm and set Operation mode, Pressure set point for switching and Hysteresis you want before shipment.
-
Wide operating temperature range (-40 to 125℃)
-
High precision and high reliability by SUS630 equivalent diaphragm, no silicone oil *High accuracy of ±1 % F.S. at 0 to 80 °C
-
Waterproof (IP67) with welded and integrated connector structure
-
Wide variety of middle-high pressure range selections (1-80 MPa)
-
Operating mode and Pressure setting point to operate switch are set according to your request / Hysteresis can be also set arbitrarily
-
UL recognized, CE marking applicable
-
Please tell us the pressure setting range etc. you want.
When purchasing, Please let us know your confirmation decisions below, assuming that you choose the rated pressure range in advance.
- Select the switch output points [Required]: 1 or 2
- Select the Operating Mode from the following two [Required]:
NO (Normally Open) :Switch ON where the pressure has reached your any setting.NC (Normally Closed):Switch OFF where the pressure has reached your any setting.
*If you select the switch output of two points, you need to set it on each switch.
The following items are the same too. - The pressure setting range to operate switch you want; Set Point [Required]:
( MPa) ※Can be set to first decimal point
The Set Point must be within 3 to 97 % F.S. of the rated pressure range.
- Do you want to set by your arbitrary about also Hysteresis? Reset Point [Optional]:
Yes ( % F.S.) or No
Hysteresis, that is, the Reset Point after the switch operation can be set at the rate you want. It must be set at 2 % F.S. or higher of the Set Point (above 3). If you do not wish to set the Reset Point at your arbitrary, we'll set up at 2 % F.S. of the Set Point by our discretion
- *Refer to [Fig.1] below for the above confirmation.
[Fig.1 Setting range and hysteresis mode]
Standard Specifications
Item | Model number (PS97-✽✽✽P) | ||||||
---|---|---|---|---|---|---|---|
Pressure range | 103P | 253P | 503P | 104P | 254P | 404P | 804P |
Pressure reference | Gauge | ||||||
Rated pressure (MPa) | 1.0 | 2.5 | 5.0 | 10.0 | 25.0 | 40.0 | 80.0 |
Maximum pressure (MPa) | 4.0 | 4.0 | 10.0 | 20.0 | 50.0 | 80.0 | 100.0 |
Break-down pressure (MPa) | 7.0 | 7.0 | 50.0 | 100.0 | 250.0 | 400.0 | 400.0 |
Operating temp. range | -40 ~ 125 °C | ||||||
Storage temp | -40 ~ 125 °C | ||||||
Operating humidity | 95 % RH maximum (No condensation) | ||||||
Pressure medium | Gases and liquids compatible with SUS630 | ||||||
Insulation resistance | 100 MΩ minimum (500 VDC) | ||||||
Pressure port | G 1/4, G 3/8, R 1/4 | ||||||
Net weight/Outline | Approx. 50 g (No cable) | ||||||
Drip-proof structure | IP67 | ||||||
Cable |
Sold separately |
||||||
Operating voltage |
9 ~ 36 V |
||||||
Consumption current | 10 mA maximum |
Switch Output
Number of output | 2 (Connecter: M12 type) or 1 (Connector: DT04-3P type) |
---|---|
Output interface | NPN open collector [*If you would like to purchase PNP open collector type, please contact us separately.] |
Setting method | Set by software |
Adjustable range | 3 ~ 97 % F.S. |
Operating mode | Hysteresis (Refer to above Fig.1) |
Overall accuracy | ±1.0 % F.S. (0 ~ 80 °C) ±1.5 % F.S. (25 ~ 100 °C) ±2.5 % F.S. (-40 ~ 125 °C) |
Hysteresis | Adjustable by software (Should be more than 2 % F.S.) |
Switching capacity | 0.25 A/ch. Maximum (Connecter: M12 type), 0.5 A Maximum (Connecter: DT04-3P type) |
Residual voltage | 0.65 V Maximum |
Output load | Vopr / (0.5 A x 0.5) ≦ RL ≦ 10kΩ |
Response | 10 ms Maximum |
Environmental Characteristics
Test item | Test conditions (at 25 ±5 °C) | Permissible change |
---|---|---|
Vibration | 10 ~ 500 Hz, 98.1 m/s2, 3 directions for 2 hours each | Change in analog output accuracy after the testas are ±1 % F.S. maximum. |
Shock | 490 m/s2 3 directions for 3 times each | |
Pressure cycling | 0 ~ Rated pressure / Rated pressure range 106 cycles | |
Moisture resistance | 40 °C, 90 ~ 95 % RH, 240 hrs. |
Model Number Designation
PS97 | - | 103 | P | - | M | G2 | - | J |
---|---|---|---|---|---|---|---|---|
Series name |
Rated pressure range 103:1.0 MPa 253:2.5 MPa 503:5.0 MPa 104: 10 MPa 254: 25 MPa 404: 40 MPa 804: 80 MPa |
Pressure reference P:Gauge (Positive) |
Connector M:M12×1 D:DT04-3P |
Fitting G2:G1/4 R2:R1/4 (Not include 80 MPa) |
Seal type J:With JIS O-ring Blank:No O-ring |
List of Part Numbers
Rated pressure range | Fitting / Connector | |||
---|---|---|---|---|
G2 (with O-ring Seal) | R2 | |||
M: M12 | D: DT04-3P | M: M12 | D: DT04-3P | |
0 ~ 1.0 MPa | PS97-103P-MG2-J | PS97-103P-DG2-J | PS97-103P-MR2 | PS97-103P-DR2 |
0 ~ 2.5 MPa | PS97-253P-MG2-J | PS97-253P-DG2-J | PS97-253P-MR2 | PS97-253P-DR2 |
0 ~ 5.0 MPa | PS97-503P-MG2-J | PS97-503P-DG2-J | PS97-503P-MR2 | PS97-503P-DR2 |
0 ~ 10 MPa | PS97-104P-MG2-J | PS97-104P-DG2-J | PS97-104P-MR2 | PS97-104P-DR2 |
0 ~ 25 MPa | PS97-254P-MG2-J | PS97-254P-DG2-J | PS97-254P-MR2 | PS97-254P-DR2 |
0 ~ 40 MPa | PS97-404P-MG2-J | PS97-404P-DG2-J | PS97-404P-MR2 | PS97-404P-DR2 |
0 ~ 80 MPa | PS97-804P-MG2-J | PS97-804P-DG2-J | ----- | ----- |
Outline Dimensions
● Connector: DT04-3P type (Switch output: 1)
Model | A’ | B’ | Fitting | CAD |
---|---|---|---|---|
PS97-✽✽✽P-DG2-J | 64.2 | 40.75 | G 1/4 | |
PS97-✽✽✽P-DR2 | 66.5 | 43.05 | R 1/4 |
● Connector: M12 type (Switch output: 2)
Model | A’ | B’ | Fitting | CAD |
---|---|---|---|---|
PS97-✽✽✽P-MG2-J | 52.25 | 40.75 | G 1/4 | |
PS97-✽✽✽P-MR2 | 54.55 | 43.05 | R 1/4 |
Fitting
-
● G 1/4
Products for 5.0 MPa or more of the standard line-up are equipped with a snubber. -
● R 1/4
Products for 5.0 MPa or more of the standard line-up are equipped with a snubber.
Pin Assignments
-
● Connector: DT04-3P model
Pin A Vcc (Power) Pin B GND (Common) Pin C SW (Output) -
● Connector: M12 model
Pin 1 Vcc (Power) Pin 2 SW2 (Output) Pin 3 GND (Common) Pin 4 SW1 (Output) Pin 5 N.C.
Wiring (schematic)
Output Load: RLmin.=Vopr/(0.5Ax0.5) , RLmax.=10kohm
Optional Cable (Sold separately)
● P/N: PS97-D152C (for DT04-3P connector) *UL not recognized / Thermal withstand: 105 °C
No. | Color | Function |
---|---|---|
A | Brown | Power |
B | Blue | GND |
C | White | SW1 |
● P/N: PS97-M152C (for M12 connector) *UL not recognized / Thermal withstand: 90 °C
No. | Color | Function |
---|---|---|
1 | Brown | Power |
2 | White | SW2 |
3 | Blue | GND |
4 | Black | SW1 |
5 | Gray | N.C. |
Operating Precautions
(DT cable’s thermal withstand is 105 °C, M12 is 90 °C)
Maintenance Precautions
Warranty
However, the following shall be excluded from the warranty:
Failure or damage caused by improper use and careless operation in violation of the Operating Instructions.
The term “Warranty” herein referred to shall imply the warranty for the product unit only, and damages from failure of the product shall be excluded.
This product is not intended to be used for equipment that may cause direct harm to life or body, or equipment that may cause significant physical damage. (Aerospace and space related equipment, railway vehicles, nuclear power equipment, military equipment, etc.)
We are not liable for any damages arising from the use of this product for purposes not intended by us.
Documents
- ●The above contents and descriptions are subject to change without notice.