NIDEC COMPONENTS logo
NIDEC COMPONENTS logo

LIST

×

×


Products

Distributor

US-English

×

Pressure switch PS60

●To buy this product, please go to the following Online Web stores.
To the Pressure switch “PS60 series” page on the DigiKey online shop
To the Pressure switch “PS60 series” page on the Mouser online shop
To the Pressure switch “PS60 series”page on the RS components online shop

PRESSURE SWITCHES WITH GAUGE

  • Applicable for negative through positive pressure with 10 mm thick slim housing
  • Suitable for use in clean rooms with easy-to-use push keys
  • Plug-in connector is provided for easy installation and maintenance
  • Space saving and mountable on DIN rails
  • Data protection by panel lock system
  • Low consumption by nondisplay mode

General specifications

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C and excitation voltage of 24 V DC.
Item 102R302R103R
Pressure reference Gauge
Rated pressure range −100 ~ 100kPa −100 ~ 300kPa −100 ~ 1000kPa
Maximum pressure 200kPa 600kPa 1500kPa
Break-down pressure 500kPa 1000kPa 2000kPa
Operating temp. range −10 ~ 50°C
Compensated temp. range 0 ~ 50°C
Operating humidity 35 ~ 85%RH(No condensation)
Storage temp. −20 ~ 70°C(Atmospheric pressure, humidity 65 %RH maximum))
Pressure medium Non-corrosive gases
Insulation resistance 100 MΩ min.(500 V DC)
Thermal error ± 3 %F.S. (0 ~ 50 °C)
Dielectric strength 500 V  AC, 60 s(Leakage current 1 mA maximum)
Pressure port M5 Female screw
Net weight Approx. 50g(Includihg cable)
Supply voltage 12 ~ 24 V ± 10 %(Including ripple percentage)
Consumption current 30mA max.
Accessories PS60 cable, DIN rail adaptor

Switch output

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C and excitation voltage of 24 V DC.
No. of outputs 2
Output interface Open collector output (NPN or PNP)
Setting method Adjustable by panel switch
Adjustable range −110 kPa (approx.) ~ “999” counts
Display Red LED ON
Repeatability ± 0.3 %F.S. maximum
Switch hysteresis 0 ~ 30 counts
Switching capacity 30 V 100 mA maximum
Residual voltage 1.2 V maximum(NPN), 2.2V maximum (PNP)
Response Approx. 5, 25, 250ms

Display

  • Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C and excitation voltage of 24 V DC.
Item102R302R103R
Display element 3-digit LED
Rated display range −100 ~ 100 kPa −100 ~ 300 kPa −0.10 ~ 1.00 MPa
Display accuracy 0 〜 50℃
(Reference temp. 25℃)
± 1 %F.S.
Resolution 1 count

ENVIRONMENTAL CHARACTERISTICS

Test itemTest conditionsPermissible change
Vibration 10 ~ 500 Hz, 1.5 mm maximum/98.1 m/s2 ,
3 directions for 2 hours each
Pressure indication and switch operating output :
± 2 %F.S., maximum each after test


Shock 196 m/s2 , 3 directions for 3 times each
Moisture resistance 40 °C, 90 ~ 95 %RH, 240 hrs
Pressure cycling 0 ~ Rated pressure, 106 cycles

MODEL NUMBER DESIGNATION

PS60-102R-NMCN

Series name

Rated pressure range

102:−100 ~ 100 kPa

103:−100 ~ 1000 kPa

302:−100 ~ 300 kPa

Pressure reference

R:Compound pressure (Negative pressure ~ Positive pressure)

Switch output interface

N:NPN open collector

P:PNP open collector

Pressure port

M:M5 female screw

Signal / power cable pullout method

CN:Connector pullout

LIST OF MODEL NUMBERS

Model numberRated pressurePressure portOutput interfaceCAD
PS60-102R-NMCN −100 ~ 100 kPa M5 Female screw NPN
PS60-102R-PMCN −100 ~ 100 kPa M5 Female screw PNP
PS60-302R-NMCN −100 ~ 300 kPa M5 Female screw NPN
PS60-302R-PMCN −100 ~ 300 kPa M5 Female screw PNP
PS60-103R-NMCN −100 ~ 1000 kPa M5 Female screw NPN
PS60-103R-PMCN −100 ~ 1000 kPa M5 Female screw PNP

CIRCUIT DIAGRAMS

SWITCH OUTPUT MODE

  • Note 1. In the Separate Mode, setting 1 corresponds to SW1, and Setting 2 corresponds to SW2.
  • Note 2. In the Window Comparator Mode, the minimum value for SW1 and SW2 corresponds to Setting 1 and the maximum value corresponds to Setting 2.

DISPLAY RANGE

  • Display range can be selected as the table.
  • Note) “–” on the table indicates that it is not selectable in relation to resolution and display lines.
  • ※ : In terms of setting display range, please verify the default mode.

OUTLINE DIMENTIONS

 

Accessories

●The above contents and descriptions are subject to change without notice. 

Products

×

page top