Strong structure with IP67 degree of protection
- Pressure sensors with IP67 degree of protection for outside-house applicants.
- Operation temperature up to 100 °C~ for pressure diaphragm.
- Voltage Output of 1 ~ 5 V DC with built-in amplifier (PA- 840), Current output of 4 ~ 20 mA DC (PA-848).
- High reliability (SUS 316 L diaphragm, oil-filled) by using double diaphragm structure.
- The most miniaturized terminal-assembly-type pressure sensor for outside-house applicants.
Model Number Designation
PA-848 - | 102 | R - | R2 | |
---|---|---|---|---|
Series name PA-848:Output Current(1-5V) |
Rated pressure range 102R :-0.1~0.1MPa |
Pressure reference G :Gauge |
Fitting R2:R 1/4 |
|
List of model numbers
Model numbers | Rated pressure | Maximum pressure | Break-down pressure | Pressure reference | Fitting | CAD |
---|---|---|---|---|---|---|
PA-848-102R-R2 | -0.1~0.1MPa | 0.2MPa | 0.3MPa | Gauge(Compound) | R 1/4 | |
PA-848-102R-G2 | -0.1~0.1MPa | 0.2MPa | 0.3MPa | Gauge(Compound) | G 1/4 | |
PA-848-352R-R2 | -0.1~0.35MPa | 0.7MPa | 1.05MPa | Gauge(Compound) | R 1/4 | |
PA-848-352R-G2 | -0.1~0.35MPa | 0.7MPa | 1.05MPa | Gauge(Compound) | G 1/4 | |
PA-848-103G-R2 | 0~1.0MPa | 2MPa | 3MPa | Gauge | R 1/4 | |
PA-848-103G-G2 | 0~1.0MPa | 2MPa | 3MPa | Gauge | G 1/4 | |
PA-848-353G-R2 | 0~3.5MPa | 4MPa | 4.5MPa | Gauge | R 1/4 | |
PA-848-353G-G2 | 0~3.5MPa | 4MPa | 4.5MPa | Gauge | G 1/4 | |
PA-848-102A-R2 | 0~0.1MPa abs. | 0.2MPa abs. | 0.3MPa abs. | Absolute | R 1/4 | |
PA-848-102A-G2 | 0~0.1MPa abs. | 0.2MPa abs. | 0.3MPa abs. | Absolute | G 1/4 |
Standard specifications
Operating temp. range | Ta (No freezing) : -20 ~ 80 °C / Pressure port : -20 ~ 100 °C |
---|---|
Operating humidity | 35~85%RH (No condensation) |
Storage temp. | -20~80℃ |
Compensated temp. range | 0 ~ 50℃ |
Pressure medium | Gas and liquid which does not corrode SUS 316L and Gas and liquid which does not corrode O-ring (Fluoro rubber) G2 Fitting |
Pressure port | R 1/4、G 1/4 |
Net weight | Approx. 250g |
Protection grade | IP67 |
Operating voltage | 21.6 ~ 26.4V DC(including ripple) |
Analog output
Pressure range | 102R | 352R | 103G | 353G | 102A |
---|---|---|---|---|---|
Output current | 4~20mA | ||||
Zero current | 12±0.2mA | 7.56±0.2mA | 4±0.2mA | 4±0.2mA | 4±0.2mA |
Span current | 16±0.4mA | ||||
Linearity/Hysteresis | ±0.5% FS | ||||
Thermal error | ZERO/ SPAN: ±0.06% FS/℃ | ||||
Load resistance | 500Ω maximum | ||||
Response | Approx. 2ms | ||||
Gravitational effect (From vertical position to horizontal position) |
± 0.3%F.S. | ± 0.1%F.S. | ± 0.05%F.S. | ± 0.3%F.S. |
Environment Characteristics
Test item | Test conditions (At 25 ± 5 °C) | Permissible change |
---|---|---|
Vibration | 10 ~ 150 Hz, 1.5 mm maximum/98.1m/s2 ,3 directions for 2 hours each | Zero current, Span current: ± 2 %F.S. maximum each |
Shock | 490m/s2, 3 directions for 3 times each | |
Pressure cycling | 0~Pr 106 cycles | |
Moisture resistance | 40℃ 90~95%RH, 240 hrs. |
Important Handling Precautions
- Never insert any foreign matters except specified pressure media into the pressure port, as this may alter the performance characteristics or damage the diaphragm, and cause malfunctions.
- Tighten wiring opening with the supplied cable gland for avoiding water intrusion.
- The cable gland and/or lid may get loose in certain usage environments and the sealing level may lower as a result. So please use a locking nut or tighten regularly.
- Atmospheric pressure is released through wiring cable.(Copal recommends a cable with built-in atmospheric-pressure-releasing tube)
- Cable wiring should be conducted in the state of power off. Shorting the output terminal and power terminal will damage the internal circuit.Please be careful not to wire incorrectly.