NIDEC COMPONENTS logo
NIDEC COMPONENTS logo

Liste

×

×


Produkte

Verteiler

EU-Deutsch

×

Treiber TF037-1001-D

●Um einen Kauf zu tätigen, wenden Sie sich an die Verteiler
oder nutzen Sie den stehenden Online-Shops unten.
Verkaufskanal  Überprüfen Sie die Verteiler.
VERKAUFSKANALKlicken Sie hier, um den Verteiler zu überprüfen.
Gehen Sie zum DigiKey Online-Shop.
Gehen Sie zum MOUSER Online-Shop.

Dedicated to the Micro Blower TF037 series

  • Dedicated to the Micro Blower TF037 series.
  • The drivers enable users to vary the speed of the motor by adjusting the control voltage of the external input.
  • Contents of the kit are Driver board and Harness (2 types).
  • Wire Harness: for Driver-Blower connection for Driver-Power connection

STANDARD SPECIFICATIONS

  • Unless otherwise specified, the environmental conditions are 23°C±5°C, normal humidity, and atmospheric pressure range 90 to 106kPa
No.ItemSpecification
1Configuration Drivers(Dedicated to the Micro Blower TF037 series)
2Rotational Speed 40,000 r/min(reference value) at  4.0kPa, 100L/min 
3Power Consumption 29W max.    at 4.0kPa, 100L/min
4Rated Voltage DC 24 V±10%
5Max. Input Current 2.0 A max.(DC)    4.0 A max.(Pulse)(Excluding inrush current)
6Running Current 1.2 A max.    at 4.0kPa, 100L/min
7Weight 32 g max.
8Operating Temperature -10~ 50 °C
9Operating Humidity Range 10~ 90 %RH  (No condensation)
10Storage Temperature -20~ 60 °C
11Storage Humidity Range 10~ 90 %RH  (No condensation)
12Resistance to Vibration To meet the Spec after the following test Non-operating
  Kind of Vibration Frequency change
Frequency Range  10 ~ 22Hz  amplitude 1mm
22 ~ 50Hz, 19.6m/s(2G acceleration)
Sweep to-and-fro, approx. 5min.
Test Time X, Y, Z directions, 60min. each
13Resistance to Shock To meet the Spec after the following test Non-operating
  Acceleration 294m/s2(30G)
Pulse Width 6ms
Shock Waven Semi-sinusoidal wave
Number of Shock X, Y, Z, directions, once per each direction

INTERFACE

CN1(CONNECTOR FOR CONTROL)SPECIFICATIONS

 

PROTECTIVE FUNCTIONS

  • Attached Driver Board is featured with the following protective functions.
Protective FunctionsDescription
High Temperature Power will be turned off when the thermistor inside the Blower exceeds 86°C.
High rotationa Power will be turned off when the rotational speed exceeds 45,000 r/min.
Overcurrent Power will be turned off when the coil current exceeds 1.9A (except start-up).
Motor Lock 1 Power will be turned off when coil current and rotational speed are in the "Motor Lock Protection Area" shown in Graph 2 below.
Motor Lock 2 Power will be turned off when the Blower does not operate even when the PRODUCT is giving command to operate.

PROTECTIVE AREA

【Monitor / Control Flow】

  • 《Restart Conditions After Blower Stop》Restart with turning the power on again.

OUTLINE DIMENSIONS

●Die oben genannten Inhalte können ohne vorherige Ankündigung geändert werden.

Produkte

×