Driver: TF037-1001-D
Dedicated to the Micro Blower TF037 series
- Dedicated to the Micro Blower TF037 series.
- The drivers enable users to vary the speed of the motor by adjusting the control voltage of the external input.
- Contents of the kit are Driver board and Harness (2 types).
- Wire Harness: for Driver-Blower connection for Driver-Power connection
STANDARD SPECIFICATIONS
- Unless otherwise specified, the environmental conditions are 23°C±5°C, normal humidity, and atmospheric pressure range 90 to 106kPa
No. | Item | Specification | |||
---|---|---|---|---|---|
1 | Configuration | Drivers(Dedicated to the Micro Blower TF037 series) | |||
2 | Rotational Speed | 40,000 r/min(reference value) at 4.0kPa, 100L/min | |||
3 | Power Consumption | 29W max. at 4.0kPa, 100L/min | |||
4 | Rated Voltage | DC 24 V±10% | |||
5 | Max. Input Current | 2.0 A max.(DC) 4.0 A max.(Pulse)(Excluding inrush current) | |||
6 | Running Current | 1.2 A max. at 4.0kPa, 100L/min | |||
7 | Weight | 32 g max. | |||
8 | Operating Temperature | -10~ 50 °C | |||
9 | Operating Humidity Range | 10~ 90 %RH (No condensation) | |||
10 | Storage Temperature | -20~ 60 °C | |||
11 | Storage Humidity Range | 10~ 90 %RH (No condensation) | |||
12 | Resistance to Vibration | To meet the Spec after the following test | Non-operating | ||
Kind of Vibration | Frequency change | ||||
Frequency Range | 10 ~ 22Hz amplitude 1mm | ||||
22 ~ 50Hz, 19.6m/s2 (2G acceleration) | |||||
Sweep | to-and-fro, approx. 5min. | ||||
Test Time | X, Y, Z directions, 60min. each | ||||
13 | Resistance to Shock | To meet the Spec after the following test | Non-operating | ||
Acceleration | 294m/s2(30G) | ||||
Pulse Width | 6ms | ||||
Shock Waven | Semi-sinusoidal wave | ||||
Number of Shock | X, Y, Z, directions, once per each direction |
INTERFACE
CN1(CONNECTOR FOR CONTROL)SPECIFICATIONS
PROTECTIVE FUNCTIONS
- Attached Driver Board is featured with the following protective functions.
Protective Functions | Description |
---|---|
High Temperature | Power will be turned off when the thermistor inside the Blower exceeds 86°C. |
High rotationa | Power will be turned off when the rotational speed exceeds 45,000 r/min. |
Overcurrent | Power will be turned off when the coil current exceeds 1.9A (except start-up). |
Motor Lock 1 | Power will be turned off when coil current and rotational speed are in the "Motor Lock Protection Area" shown in Graph 2 below. |
Motor Lock 2 | Power will be turned off when the Blower does not operate even when the PRODUCT is giving command to operate. |
PROTECTIVE AREA
【Monitor / Control Flow】
- 《Restart Conditions After Blower Stop》Restart with turning the power on again.
OUTLINE DIMENSIONS
- ●The above contents and descriptions are subject to change without notice.