Pressure transducer with amp. PA-500
Pressure transducer with amp. PA-500
- High output gain by built-in hybrid electronic amp.
- Built-in temperature compensation function (0 ~ 50 °C)
- Pressure medium compatible with both liquid and gas pressures (Gauge)
Model Number Designation
PA-500- | 501 | D | -06 |
---|---|---|---|
Series name |
Rated pressure range 101:0 ~ 9.81 kPa {0 ~ 0.1 kgf/cm2} |
Pressure reference G:Gauge |
Thermal error 06:± 0.06 % F.S./°C |
List of model numbers
Model numbers | Rated pressure | Maximum pressure | Break-down pressure | Thermal error | Pressure port | CAD |
---|---|---|---|---|---|---|
PA-500-101G-10 | 0 ~ 9.81 kPa {0 ~ 0.1 kgf/cm2} | 19.6kPa {0.2 kgf/cm2} | 49 kPa {0.5 kgf/cm2} | ± 0.1 % F.S./°C | R 1/4 (PT 1/4) | |
PA-500-501G-10 | 0 ~ 49.0 kPa {0 ~ 0.5} kgf/cm2} | 98.1kPa {1 kgf/cm2} | 245 kPa {2.5 kgf/cm2} | ± 0.1 % F.S./°C | R 1/4 (PT 1/4) | |
PA-500-501G-06 | 0 ~ 49.0 kPa {0 ~ 0.5} kgf/cm2} | 98.1kPa {1 kgf/cm2} | 245 kPa {2.5 kgf/cm2} | ± 0.06 % F.S./°C | R 1/4 (PT 1/4) | |
PA-500-102G-06 | 0 ~ 98.1 kPa {0 ~ 1} kgf/cm2} | 196kPa {2 kgf/cm2} | 490 kPa {5 kgf/cm2} | ± 0.06 % F.S./°C | R 1/4 (PT 1/4) | |
PA-500-102G-10 | 0 ~ 98.1 kPa {0 ~ 1} kgf/cm2} | 196kPa {2 kgf/cm2} | 490 kPa {5 kgf/cm2} | ± 0.1 % F.S./°C | R 1/4 (PT 1/4) | |
PA-500-352G-10 | 0 ~ 343 kPa {0 ~ 3.5} kgf/cm2} | 686 kPa {7 kgf/cm2} | 1030 kPa {10.5 kgf/cm2} | ± 0.1 % F.S./°C | R 1/4 (PT 1/4) | |
PA-500-352G-06 | 0 ~ 343 kPa {0 ~ 3.5} kgf/cm2} | 686 kPa {7 kgf/cm2} | 1030 kPa {10.5 kgf/cm2} | ± 0.06 % F.S./°C | R 1/4 (PT 1/4) | |
PA-500-502G-06 | 0 ~ 490 kPa {0 ~ 5} kgf/cm2} | 981 kPa {10 kgf/cm2} | 1471 kPa {15 kgf/cm2} | ± 0.06 % F.S./°C | R 1/4 (PT 1/4) | |
PA-500-502G-10 | 0 ~ 490 kPa {0 ~ 5} kgf/cm2} | 981 kPa {10 kgf/cm2} | 1471 kPa {15 kgf/cm2} | ± 0.1 % F.S./°C | R 1/4 (PT 1/4) | |
PA-500-103G-10 | 0 ~ 981 kPa {0 ~ 10} kgf/cm2} | 1961 kPa {20 kgf/cm2} | 2941 kPa {30 kgf/cm2} | ± 0.1 % F.S./°C | R 1/4 (PT 1/4) | |
PA-500-103G-06 | 0 ~ 981 kPa {0 ~ 10} kgf/cm2} | 1961 kPa {20 kgf/cm2} | 2941 kPa {30 kgf/cm2} | ± 0.06 % F.S./°C | R 1/4 (PT 1/4) | |
PA-500-102V-06 | 0 ~ −98.1 kPa {0 ~ −1} kgf/cm2} | 196 kPa {2 kgf/cm2} | 490 kPa {5 kgf/cm2} | ± 0.06 % F.S./°C | G 1/4 (PF 1/4) | |
PA-500-102V-10 | 0 ~ −98.1 kPa {0 ~ −1} kgf/cm2} | 196 kPa {2 kgf/cm2} | 490 kPa {5 kgf/cm2} | ± 0.1 % F.S./°C | G 1/4 (PF 1/4) |
Standard specifications
- Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 V DC.
Pressure reference | Gauge、Gauge(Vacuum) |
---|---|
Pressure medium | Non-corrosive gases / Non-corrosive liquids |
Operating temp. range | − 20 ~ 80°C |
Compensated temp. range | 0 ~ 50°C |
Operating humidity | 35 ~ 85%RH(No condensation) |
Storage temp. | −20 ~ 80°C(Atmospheric pressure, humidity 65 %RH maximum) |
Insulation resistance | 100 MΩ minimum (500 V DC) |
Dielectric strength | 500 V DC, 60 s(Leakage current 1 mA maximum) |
Pressure port | R1/4(PT 1/4)、G 1/4 (PT 1/4) |
Net weight | Approx. 85g |
Supply voltage | 12 ~ 24 ± 10 % |
Ripple content | 10 % (P-P) maximum |
Consumption current | 20 mA maximum |
Analog output
Pressure range | 101G | 501G | 102G | 352G | 502G | 103G | 102V |
---|---|---|---|---|---|---|---|
Output voltage | 1 ~ 5 V | ||||||
Zero voltage | 1 ± 0.04 V(at 25 °C) | ||||||
Span voltage | 4 ± 0.04 V(at 25 °C) | ||||||
Output current | 1 mA max. (Load resistance 5 kΩ min.) | ||||||
Linearity/Hysteresis | ± 0.5%F.S. | ± 0.3%F.S. | ± 0.5%F.S. | ||||
Thermal error/ZERO 0 ~ 50 °C (Reference temp.: 25 °C) |
± 0.1%F.S./°C | ± 0.06/0.1%F.S./°C | |||||
Thermal error/SPAN 0 ~ 50 °C (Reference temp.: 25 °C) |
± 0.1 %F.S./°C | ± 0.06/0.1 %F.S./°C | |||||
Supply voltage effect | ± 0.1V maximum | ||||||
Response | Approx. 1 ms |
Environment Characteristics
Test item | Test conditions (At 25 ± 5 °C) | Permissible change |
---|---|---|
Vibration | 10 ~ 500 Hz, 1.5 mm maximum/98.1 m/s2, 3 directions for 2 hours each |
Zero voltage/Span voltage: ± 1 %F.S. maximum each |
Shock | 981 m/s2, 3 directions for 3 times each | |
Pressure cycling | 0 ~ Rated pressure, 106 cycles | |
Moisture resistance | 40 °C, 90 ~ 95 %RH, 240 hrs. |
Outline Dimensions
Internal Circuit Diagram
Documents
- ●The above contents and descriptions are subject to change without notice.