High operating temperature up to 125 ℃
-
Operating temperature range up to 125 °C
-
Low thermal derating factor
-
Higher hold currents at elevated temperature
-
Choice of operating cuttents
-
Resettable fault protection of general electronic equipment
-
RoHS compliant and halogen free
Electrical Characteristics
Model | Maximum Voltage (V max) | Maximum Current (I max) | at 23 ℃ | |||||
---|---|---|---|---|---|---|---|---|
Hold Current (Ihold) | Trip Current (Itrip) | R min ※1 | R1 max ※2 | Max. Time to Trip | Tripped Power Dissipation※3 | |||
PRCP-RHT070 | 16 VDC | 40 A | 0.70 A (at 23 ℃) | 1.40 A (at 23 ℃) | 0.300 Ω※1 (at 23 ℃) | 0.800 Ω※2 (at 23 ℃) | 4.0 Sec (at 3.5 A, at 23 ℃) |
1.4 W※3 (at 23 ℃) |
PRCP-RHT200 | 16 VDC | 100 A | 2.00 A (at 23 ℃) | 3.80 A (at 23 ℃) | 0.045 Ω※1 (at 23 ℃) | 0.110 Ω※2 (at 23 ℃) | 3.0 Sec (at 12.5 A, at 23 ℃) |
1.4 W※3 (at 23 ℃) |
PRCP-RHT450 | 16 VDC | 100 A | 4.50 A (at 23 ℃) | 7.80 A (at 23 ℃) | 0.022 Ω※1 (at 23 ℃) | 0.054 Ω※2 (at 23 ℃) | 3.0 Sec (at 22.5 A, at 23 ℃) |
3.6 W※3 (at 23 ℃) |
PRCP-RHT650 | 16 VDC | 100 A | 6.50 A (at 23 ℃) | 12.00 A (at 23 ℃) | 0.011 Ω※1 (at 23 ℃) | 0.026 Ω※2 (at 23 ℃) | 5.5 Sec (at 32.5 A, at 23 ℃) |
4.3 W※3 (at 23 ℃) |
PRCP-RHT750 | 16 VDC | 100 A | 7.50 A (at 23 ℃) | 13.10 A (at 23 ℃) | 0.0094 Ω※1 (at 23 ℃) | 0.022 Ω※2 (at 23 ℃) | 7.0 Sec (at 37.5 A, at 23 ℃) |
4.5 W※3 (at 23 ℃) |
PRCP-RHT1300 | 16 VDC | 100 A | 13.00 A (at 23 ℃) | 24.00 A (at 23 ℃) | 0.0041 Ω※1 (at 23 ℃) | 0.010 Ω※2 (at 23 ℃) | 13.0 Sec (at 60.0 A, at 23 ℃) |
6.9 W※3 (at 23 ℃) |
Thermal Derating Chart
Model | Ambient operating temperature: Ihold (A) | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
-40 ℃ | -20 ℃ | 0 ℃ | 23 ℃ | 40 ℃ | 50 ℃ | 60 ℃ | 70℃ | 85 ℃ | 125℃ | |
PRCP-RHT070 | -40 ℃: 0.95 | -20 ℃: 0.87 | 0 ℃: 0.79 | 23 ℃: 0.70 | 40 ℃: 0.62 | 50 ℃: 0.56 | 60 ℃: 0.51 | 70 ℃: 0.47 | 85 ℃: 0.39 | 125 ℃: 0.17 |
PRCP-RHT200 | -40 ℃: 2.71 | -20 ℃: 2.49 | 0 ℃: 2.26 | 23 ℃: 2.00 | 40 ℃: 1.77 | 50 ℃: 1.60 | 60 ℃: 1.46 | 70 ℃: 1.34 | 85 ℃: 1.11 | 125 ℃: 0.49 |
PRCP-RHT450 | -40 ℃: 6.10 | -20 ℃: 5.60 | 0 ℃: 5.10 | 23 ℃: 4.50 | 40 ℃: 4.00 | 50 ℃: 3.60 | 60 ℃: 3.30 | 70 ℃: 3.00 | 85 ℃: 2.50 | 125 ℃: 1.10 |
PRCP-RHT650 | -40 ℃: 8.80 | -20 ℃: 8.10 | 0 ℃: 7.40 | 23 ℃: 6.50 | 40 ℃: 5.70 | 50 ℃: 5.30 | 60 ℃: 4.80 | 70 ℃: 4.30 | 85 ℃: 3.60 | 125 ℃: 1.60 |
PRCP-RHT750 | -40 ℃: 10.20 | -20 ℃: 9.40 | 0 ℃: 8.60 | 23 ℃: 7.50 | 40 ℃: 6.60 | 50 ℃: 6.10 | 60 ℃: 5.60 | 70 ℃: 5.00 | 85 ℃: 4.10 | 125 ℃: 1.90 |
PRCP-RHT1300 | -40 ℃: 17.70 | -20 ℃: 16.30 | 0 ℃: 14.80 | 23 ℃: 13.00 | 40 ℃: 11.40 | 50 ℃: 10.50 | 60 ℃: 9.60 | 70 ℃: 8.60 | 85 ℃: 7.20 | 125 ℃: 3.30 |
Environmental Characteristics
Operating Temperature | -40 ℃ ~ +125 ℃ |
---|---|
Storage Tempetature | -40 ℃ ~ +85 ℃ |
Passive Aging | 85 ℃, 1000 h: ±15 % typical resistance change |
Humidity Aging | 85 ℃, 85 %RH, 1000 h: ±15 % typical resistance change |
Thermal Shock |
MIL-STD-202, Method 107,+125 ℃ ~ -40 ℃, 10 cycles : ±10 % typical resistance change |
Solvent Resistance |
MIL-STD-202 method 215: No change |
Vibration | MIL-STD-883C, Method 2007.1, Condition A: No change |
MSL (Moisture Sensitivity Level) | Level 1, J-STD-020 |
Test Procedures and Requirements
Item | Test Condition | Accept / Reject Criteria |
---|---|---|
Visual/Mech. | Test condition: Verify dimensions and materials | Accept / Reject criteria: Per P.R.C.P. physical description |
Resistance | Test condition: In still air at 23 ℃ | Accept / Reject criteria: R min ≤ R ≤ R1 max |
Time to Trip | Test condition: At specified current, V max, 23 ℃ | Accept / Reject criteria: T ≤ max. time to trip (Sec) |
Hold Current | Test condition: 30 min. at Ihold , 23 ℃, still air | Accept / Reject criteria: No trip |
Trip Cycle Life | Test condition: V max, I max, 100 cycles | Accept / Reject criteria: No arcing or burning |
Trip Endurance | Test condition: V max, 48 h | Accept / Reject criteria: No arcing or burning |
Solderability | Test condition: 245 ℃ ± 5 ℃, 5 seconds | Accept / Reject criteria: 95% min. coverage |
Product Dimensions
Model | A | B | C | D | E | F | Style | |
---|---|---|---|---|---|---|---|---|
Max. | Max. | Nom. | Tol. ± | Min. | Max. | Nom. | ||
PRCP-RHT070 | 6.86 (0.27) |
10.8 (0.425) |
5.1 (0.201) |
0.7 (0.028) |
7.6 (0.30) |
3.0 (0.12) |
0.51 (0.020) |
style 3 |
PRCP-RHT200 | 9.4 (0.37) |
14.0 (0.55) |
5.1 (0.201) |
0.7 (0.028) |
7.6 (0.30) |
3.0 (0.12) |
0.51 (0.020) |
style 1 |
PRCP-RHT450 | 10.4 (0.41) |
15.6 (0.61) |
5.1 (0.201) |
0.7 (0.028) |
7.6 (0.30) |
3.0 (0.12) |
0.81 (0.032) |
style 2 |
PRCP-RHT650 | 12.7 (0.50) |
22.2 (0.88) |
5.1 (0.201) |
0.7 (0.028) |
7.6 (0.30) |
3.0 (0.12) |
0.81 (0.032) |
style 2 |
PRCP-RHT750 | 14.0 (0.55) |
23.5 (0.93) |
5.1 (0.201) |
0.7 (0.028) |
7.6 (0.30) |
3.0 (0.12) |
0.81 (0.032) |
style 2 |
PRCP-RHT1300 | 23.5 (0.925) |
28.7 (1.17) |
10.2 (0.402) |
0.7 (0.028) |
7.6 (0.30) |
3.6 (0.14) |
1.0 (0.040) |
style 2 |
PRCP-RHT070 |
Style:Style 3
A:Max. 6.86 (0.27) B:Max. 10.8 (0.425) C:Nom. 5.1 (0.201) C:Tol. ± 0.7 (0.028) D:Min. 7.6 (0.30) E:Max. 3.0 (0.12) F:Nom. 0.51 (0.020) |
---|---|
PRCP-RHT200 |
Style:Style 1
A:Max. 9.4 (0.37) B:Max. 14.0 (0.55) C:Nom. 5.1 (0.201) C:Tol. ± 0.7 (0.028) D:Min. 7.6 (0.30) E:Max. 3.0 (0.12) F:Nom. 0.51 (0.020) |
PRCP-RHT450 |
Style:Style 2
A:Max. 10.4 (0.41) B:Max. 15.6 (0.61) C:Nom. 5.1 (0.201) C:Tol. ± 0.7 (0.028) D:Min. 7.6 (0.30) E:Max. 3.0 (0.12) F:Nom. 0.81 (0.032) |
PRCP-RHT650 |
Style:Style 2
A:Max. 12.7 (0.50) B:Max. 22.2 (0.88) C:Nom. 5.1 (0.201) C:Tol. ± 0.7 (0.028) D:Min. 7.6 (0.30) E:Max. 3.0 (0.12) F:Nom. 0.81 (0.032) |
PRCP-RHT750 |
Style:Style 2
A:Max. 14.0 (0.55) B:Max. 23.5 (0.93) C:Nom. 5.1 (0.201) C:Tol. ± 0.7 (0.028) D:Min. 7.6 (0.30) E:Max. 3.0 (0.12) F:Nom. 0.81 (0.032) |
PRCP-RHT1300 |
Style:Style 2
A:Max. 23.5 (0.925) B:Max. 28.7 (1.17) C:Nom. 10.2 (0.402) C:Tol. ± 0.7 (0.028) D:Min. 7.6 (0.30) E:Max. 3.6 (0.14) F:Nom. 1.0 (0.040) |
Warranty
However, the following shall be excluded from the warranty:
Failure or damage caused by improper use and careless operation in violation of the catalog and specification.
The term “Warranty” herein referred to shall imply the warranty for the product unit only, and damages from failure of the product shall be excluded.
This product is not intended to be used for equipment that may cause direct harm to life or body, or equipment that may cause significant physical damage. (Aerospace and space related equipment, railway vehicles, nuclear power equipment, military equipment, etc.) We are not liable for any damages arising from the use of this product for purposes not intended by us.
Furthermore, we ask you to perform a swift incoming inspection for delivered products and we wouldalso appreciate if full attention is given to the storage conditions of the product.
Documents
Environmental Data
- ●The above contents and descriptions are subject to change without notice.