NIDEC COMPONENTS logo
NIDEC COMPONENTS logo

LIST

×

×


Products

Distributor

US-English

×

Polymer Resettable Circuit Protector PRCP-RHT

●To buy this product, please go to the following Online Web stores.
To the Polymer Resettable Circuit Protector “PRCP-RHT series” page on the Chip1stop online shop

High operating temperature up to 125 ℃

 

FeaturesFeatures
  • Operating temperature range up to 125 °C

  • Low thermal derating factor

  • Higher hold currents at elevated temperature

  • Choice of operating cuttents

  • Resettable fault protection of general electronic equipment

  • RoHS compliant and halogen free

 

Electrical Characteristics

ModelMaximum Voltage
 (V max)
Maximum Current
 (I max)
at 23 ℃
Hold Current
 (Ihold)
Trip Current
 (Itrip)
R min
※1
R1 max
※2
Max. Time
to Trip
Tripped Power
Dissipation※3
PRCP-RHT070 16 VDC 40 A 0.70 A (at 23 ℃) 1.40 A (at 23 ℃) 0.300 Ω※1 (at 23 ℃) 0.800 Ω※2 (at 23 ℃) 4.0 Sec
 (at 3.5 A, at 23 ℃)
1.4 W※3 (at 23 ℃)
PRCP-RHT200 16 VDC 100 A 2.00 A (at 23 ℃) 3.80 A (at 23 ℃) 0.045 Ω※1 (at 23 ℃) 0.110 Ω※2 (at 23 ℃) 3.0 Sec
 (at 12.5 A, at 23 ℃)
1.4 W※3 (at 23 ℃)
PRCP-RHT450 16 VDC 100 A 4.50 A (at 23 ℃) 7.80 A (at 23 ℃) 0.022 Ω※1 (at 23 ℃) 0.054 Ω※2 (at 23 ℃) 3.0 Sec
 (at 22.5 A, at 23 ℃)
3.6 W※3 (at 23 ℃)
PRCP-RHT650 16 VDC 100 A 6.50 A (at 23 ℃) 12.00 A (at 23 ℃) 0.011 Ω※1 (at 23 ℃) 0.026 Ω※2 (at 23 ℃) 5.5 Sec
 (at 32.5 A, at 23 ℃)
4.3 W※3 (at 23 ℃)
PRCP-RHT750 16 VDC 100 A 7.50 A (at 23 ℃) 13.10 A (at 23 ℃) 0.0094 Ω※1 (at 23 ℃) 0.022 Ω※2 (at 23 ℃) 7.0 Sec
 (at 37.5 A, at 23 ℃)
4.5 W※3 (at 23 ℃)
PRCP-RHT1300 16 VDC 100 A 13.00 A (at 23 ℃) 24.00 A (at 23 ℃) 0.0041 Ω※1 (at 23 ℃) 0.010 Ω※2 (at 23 ℃) 13.0 Sec
 (at 60.0 A, at 23 ℃)
6.9 W※3 (at 23 ℃)
※1) R min = Minimum resistance (Initial)
※2) R1 max = Maximum resistance one hour after past trip of past reflow
※3) Typical value

Thermal Derating Chart

● Ambient operating temperature: Ihold (A)
ModelAmbient operating temperature: Ihold (A)
-40 ℃-20 ℃0 ℃23 ℃40 ℃50 ℃60 ℃ 70℃85 ℃ 125℃
PRCP-RHT070   -40 ℃: 0.95   -20 ℃: 0.87      0 ℃: 0.79    23 ℃: 0.70    40 ℃: 0.62    50 ℃: 0.56    60 ℃: 0.51    70 ℃: 0.47    85 ℃: 0.39  125 ℃: 0.17
PRCP-RHT200   -40 ℃: 2.71   -20 ℃: 2.49      0 ℃: 2.26    23 ℃: 2.00    40 ℃: 1.77    50 ℃: 1.60    60 ℃: 1.46    70 ℃: 1.34    85 ℃: 1.11  125 ℃: 0.49
PRCP-RHT450   -40 ℃: 6.10   -20 ℃: 5.60      0 ℃: 5.10    23 ℃: 4.50    40 ℃: 4.00    50 ℃: 3.60    60 ℃: 3.30    70 ℃: 3.00    85 ℃: 2.50  125 ℃: 1.10
PRCP-RHT650   -40 ℃: 8.80   -20 ℃: 8.10      0 ℃: 7.40    23 ℃: 6.50    40 ℃: 5.70    50 ℃: 5.30    60 ℃: 4.80    70 ℃: 4.30    85 ℃: 3.60  125 ℃: 1.60
PRCP-RHT750   -40 ℃: 10.20   -20 ℃: 9.40      0 ℃: 8.60    23 ℃: 7.50    40 ℃: 6.60    50 ℃: 6.10    60 ℃: 5.60    70 ℃: 5.00    85 ℃: 4.10  125 ℃: 1.90
PRCP-RHT1300   -40 ℃: 17.70   -20 ℃: 16.30      0 ℃: 14.80    23 ℃: 13.00    40 ℃: 11.40    50 ℃: 10.50    60 ℃: 9.60    70 ℃: 8.60    85 ℃: 7.20  125 ℃: 3.30

Environmental Characteristics

Operating Temperature -40 ℃ ~ +125 ℃
Storage Tempetature -40 ℃ ~ +85 ℃
Passive Aging 85 ℃, 1000 h: ±15 % typical resistance change
Humidity Aging 85 ℃, 85 %RH, 1000 h: ±15 % typical resistance change
Thermal Shock

MIL-STD-202, Method 107,-40 ℃ ~ +125 ℃, 10 cycles

: ±10 % typical resistance change
Solvent Resistance

MIL-STD-202 method 215: No change

Vibration MIL-STD-883C, Method 2007.1, Condition A: No change
MSL (Moisture Sensitivity Level) Level 1, J-STD-020

Test Procedures and Requirements

ItemTest ConditionAccept / Reject Criteria
Visual/Mech. Test condition: Verify dimensions and materials Accept / Reject criteria: Per P.R.C.P. physical description
Resistance Test condition: In still air at 23 ℃ Accept / Reject criteria: R min ≤ R ≤ R1 max
Time to Trip Test condition: At specified current, V max, 23 ℃ Accept / Reject criteria: T ≤ max. time to trip (Sec)
Hold Current Test condition: 30 min. at Ihold , 23 ℃, still air Accept / Reject criteria: No trip
Trip Cycle Life Test condition: V max, I max, 100 cycles Accept / Reject criteria: No arcing or burning
Trip Endurance Test condition: V max, 48 h Accept / Reject criteria: No arcing or burning
Solderability Test condition: 245 ℃ ± 5 ℃, 5 seconds Accept / Reject criteria: 95% min. coverage

Product Dimensions

Unit: mm (inch)
ModelABCDEFStyle
Max.Max.Nom.Tol. ±Min.Max.Nom.
PRCP-RHT070 6.86
(0.27)
10.8
(0.425)
5.1
(0.201)
0.7
(0.028)
7.6
(0.30)
3.0
(0.12)
0.51
(0.020)
style 3
PRCP-RHT200 9.4
(0.37)
14.0
(0.55)
5.1
(0.201)
0.7
(0.028)
7.6
(0.30)
3.0
(0.12)
0.51
(0.020)
style 1
PRCP-RHT450 10.4
(0.41)
15.6
(0.61)
5.1
(0.201)
0.7
(0.028)
7.6
(0.30)
3.0
(0.12)
0.81
(0.032)
style 2
PRCP-RHT650 12.7
(0.50)
22.2
(0.88)
5.1
(0.201)
0.7
(0.028)
7.6
(0.30)
3.0
(0.12)
0.81
(0.032)
style 2
PRCP-RHT750 14.0
(0.55)
23.5
(0.93)
5.1
(0.201)
0.7
(0.028)
7.6
(0.30)
3.0
(0.12)
0.81
(0.032)
style 2
PRCP-RHT1300 23.5
(0.925)
28.7
(1.17)
10.2
(0.402)
0.7
(0.028)
7.6
(0.30)
3.6
(0.14)
1.0
(0.040)
style 2
PRCP-RHT070
Style:Style 3
A:Max. 6.86 (0.27)
B:Max. 10.8 (0.425)
C:Nom. 5.1 (0.201)
C:Tol. ± 0.7 (0.028)
D:Min. 7.6 (0.30)
E:Max. 3.0 (0.12)
F:Nom. 0.51 (0.020)
PRCP-RHT200
Style:Style 1
A:Max. 9.4 (0.37)
B:Max. 14.0 (0.55)
C:Nom. 5.1 (0.201)
C:Tol. ± 0.7 (0.028)
D:Min. 7.6 (0.30)
E:Max. 3.0 (0.12)
F:Nom. 0.51 (0.020)
PRCP-RHT450
Style:Style 2
A:Max. 10.4 (0.41)
B:Max. 15.6 (0.61)
C:Nom. 5.1 (0.201)
C:Tol. ± 0.7 (0.028)
D:Min. 7.6 (0.30)
E:Max. 3.0 (0.12)
F:Nom. 0.81 (0.032)
PRCP-RHT650
Style:Style 2
A:Max. 12.7 (0.50)
B:Max. 22.2 (0.88)
C:Nom. 5.1 (0.201)
C:Tol. ± 0.7 (0.028)
D:Min. 7.6 (0.30)
E:Max. 3.0 (0.12)
F:Nom. 0.81 (0.032)
PRCP-RHT750
Style:Style 2
A:Max. 14.0 (0.55)
B:Max. 23.5 (0.93)
C:Nom. 5.1 (0.201)
C:Tol. ± 0.7 (0.028)
D:Min. 7.6 (0.30)
E:Max. 3.0 (0.12)
F:Nom. 0.81 (0.032)
PRCP-RHT1300
Style:Style 2
A:Max. 23.5 (0.925)
B:Max. 28.7 (1.17)
C:Nom. 10.2 (0.402)
C:Tol. ± 0.7 (0.028)
D:Min. 7.6 (0.30)
E:Max. 3.6 (0.14)
F:Nom. 1.0 (0.040)

Warranty

The Warranty period for the product shall be one year. A failure due to causes attributed to design or manufacturing defects during the period one year from the date of delivery shall be repaired or replaced free of charge.
However, the following shall be excluded from the warranty:

Failure or damage caused by improper use and careless operation in violation of the catalog and specification.

Failure or damage caused by inappropriate modification, adjustment, or repair.
Failure or damage caused by technically and sci en tif i cally unpredictable factors.
Failure or damage caused by acts of God, fire, or other unavoidable accidents.

The term “Warranty” herein referred to shall imply the warranty for the product unit only, and damages from failure of the product shall be excluded.
This product is not intended to be used for equipment that may cause direct harm to life or body, or equipment that may cause significant physical damage. (Aerospace and space related equipment, railway vehicles, nuclear power equipment, military equipment, etc.) We are not liable for any damages arising from the use of this product for purposes not intended by us.
Furthermore, we ask you to perform a swift incoming inspection for delivered products and we wouldalso appreciate if full attention is given to the storage conditions of the product.

Environmental Data

●The above contents and descriptions are subject to change without notice. 

Products

×