Pressure transducer P-2000
Pressure Transmitter P-2000
- Compact and light weight
- For non-corrosive gases
- Dual in line package
- Pressure range ~9.81, ~981 kPa {~0.1, ~10 kgf/cm2}
Model Number Designation
P-2000 - | 501 | G- | 15 - | BN |
---|---|---|---|---|
Series name |
Rated pressure range 101:0 ~ 9.81 kPa {0 ~ 0.1 kgf/cm2 } |
Pressure reference G:Gauge |
Thermal error 15:± 0.15 % (± 0.12 %) F.S./°C |
Terminal direction AN:Same direction as the pressure port |
List of model numbers
Model Number | Rated pressure range | Maximum pressure | Break-down pressure | CAD |
---|---|---|---|---|
➡ P-2000-101G-15-AN | 9.81 kPa {0.1 kgf/cm2} | 19.6 kPa {0.2 kgf/cm2} | 49 kPa {0.5 kgf/cm2} | |
P-2000-101G-15-BN | 9.81 kPa {0.1 kgf/cm2} | 19.6 kPa {0.2 kgf/cm2} | 49 kPa {0.5 kgf/cm2} | |
➡ P-2000-501G-15-AN | 49 kPa {0.5 kgf/cm2} | 98.1 kPa {1.0 kgf/cm2} | 245 kPa {2.5 kgf/cm2} | |
P-2000-501G-15-BN | 49 kPa {0.5 kgf/cm2} | 98.1 kPa {1.0 kgf/cm2} | 245 kPa {2.5 kgf/cm2} | |
➡ P-2000-102G-15-AN | 98.1 kPa {1.0 kgf/cm2} | 196 kPa {2.0 kgf/cm2} | 490 kPa {5 kgf/cm2} | |
P-2000-102G-15-BN | 98.1 kPa {1.0 kgf/cm2} | 196 kPa {2.0 kgf/cm2} | 490 kPa {5 kgf/cm2} | |
➡ P-2000-352G-15-AN | 343 kPa {3.5 kgf/cm2} | 686 kPa {7.0 kgf/cm2} | 1030 kPa {10.5 kgf/cm2} | |
P-2000-352G-15-BN | 343 kPa {3.5 kgf/cm2} | 686 kPa {7.0 kgf/cm2} | 1030 kPa {10.5 kgf/cm2} | |
➡ P-2000-502G-15-AN | 490 kPa {5 kgf/cm2} | 981 kPa {10 kgf/cm2} | 1471 kPa {15 kgf/cm2} | |
P-2000-502G-15-BN | 490 kPa {5 kgf/cm2} | 981 kPa {10 kgf/cm2} | 1471 kPa {15 kgf/cm2} | |
➡ P-2000-702G-15-AN | 686 kPa {7 kgf/cm2} | 1373 kPa {14 kgf/cm2} | 1961 kPa {20 kgf/cm2} | |
P-2000-702G-15-BN | 686 kPa {7 kgf/cm2} | 1373 kPa {14 kgf/cm2} | 1961 kPa {20 kgf/cm2} | |
➡ P-2000-103G-15-AN | 981 kPa {10.0 kgf/cm2} | 1471 kPa {15.0 kgf/cm2} | 1961 kPa {20 kgf/cm2} | |
P-2000-103G-15-BN | 981 kPa {10.0 kgf/cm2} | 1471 kPa {15.0 kgf/cm2} | 1961 kPa {20 kgf/cm2} |
The AN version, marked ➡ is manufactured upon receipt of order basis
Standard specifications
Operating temp. range | − 20 ~ 80℃ |
---|---|
Compensated temp. range | 0 ~ 50℃ |
Operating humidity | 35 ~ 85%RH(No condensation) |
Storage temp. | − 20 ~ 80℃(Atmospheric pressure, humidity 65 %RH maximum) |
Bridge resistance | 3300 ± 30 %Ω |
Pressure medium | Non-corrosive gases |
Insulation resistance | 100 MΩ(500 V DC) Min. |
Dielectric strength | 500 V AC, 60 s(Leakage current 1 mA maximum) |
Pressure port | φ 3.2mm |
Analog output
Pressure range | Offset voltage | Span voltage | Linearity/Hysteresis | ZERO %F.S./°C | SPAN %F.S./°C | Response |
---|---|---|---|---|---|---|
0 ~ 9.81 kPa {0 ~ 0.1 kgf/cm2} |
± 20mV | 50 ± 20mV | ± 0.3%F.S. | ± 0.15 | ± 0.05 | Approx. 1ms |
0 ~ 49.0 kPa {0 ~ 0.5 kgf/cm2} |
± 15mV | 90 ± 30mV | ± 0.3%F.S. | ± 0.12 | ± 0.04 | Approx. 1ms |
0 ~ 98.1 kPa {0 ~ 1 kgf/cm2} |
± 15mV | 90 ± 30mV | ± 0.3%F.S. | ± 0.12 | ± 0.04 | Approx. 1ms |
0 ~ 343 kPa {0 ~ 3.5 kgf/cm2} |
± 15mV | 90 ± 30mV | ± 0.3%F.S. | ± 0.12 | ± 0.04 | Approx. 1ms |
0 ~ 490 kPa {0 ~ 5 kgf/cm2} |
± 15mV | 90 ± 30mV | ± 0.3%F.S. | ± 0.12 | ± 0.04 | Approx. 1ms |
0 ~ 686 kPa {0 ~ 7 kgf/cm2} |
± 15mV | 90 ± 30mV | ± 0.3%F.S. | ± 0.12 | ± 0.04 | Approx. 1ms |
0 ~ 981 kPa {0 ~ 10 kgf/cm2} |
± 15mV | 90 ± 30mV | ± 0.3%F.S. | ± 0.12 | ± 0.04 | Approx. 1ms |
Environment Characteristics
Test item | Test conditions (At 25 ± 5 °C) | Permissible change |
---|---|---|
Vibration | 10 ~ 500 Hz, 1.5 mm maximum/98.1 m/s2, 3 directions for 2 hours each |
Offset voltage/Span voltage: |
Shock | 981 m/s2, 3 directions for 3 times each | |
Pressure cycling | 0 ~ Rated pressure, 106 cycles | |
Moisture resistance | 40 °C, 90 ~ 95 %RH, 240 hrs. |
※ P-2000 series can be operated at the vacuum pressure.
Outline Dimensions
Internal Circuit Diagram
Terminal Number
Documents
- ●The above contents and descriptions are subject to change without notice.