240 V rated model for AC line
-
Maximum voltage 240 VAC
-
Radial leaded devices
-
Cured, flame retardant epoxy polymer insulating material meets UL94 V-0
-
Bulk packaging, tape and reel available
-
Resettable circuit protection
-
RoHS compliant and halogen free
-
Agency recognition: cULus, TÜV
-
Electrical Characteristics
Model | Maximum Voltage (V max) | Maximum Current (I max) | at 23 ℃ | ||||||
---|---|---|---|---|---|---|---|---|---|
Operating Voltage | Interrupt Voltage | Hold Current (Ihold) | Trip Current (Itrip) | R min ※1 | R1 max ※2 | Time to Trip | Tripped Power Dissipation※3 | ||
PRCP-RM005/240 | 240 VAC | 265 VAC | 1.0 A | 0.05 A (at 23 ℃) | 0.12 A (at 23 ℃) | 18.50 Ω※1 (at 23 ℃) | 65.00 Ω※2 (at 23 ℃) | 10.0 Sec (at 0.25 A, at 23 ℃) |
0.9 W※3 (at 23 ℃) |
PRCP-RM008/240 | 240 VAC | 265 VAC | 1.2 A | 0.08 A (at 23 ℃) | 0.19 A (at 23 ℃) | 7.40 Ω※1 (at 23 ℃) | 26.00 Ω※2 (at 23 ℃) | 10.0 Sec (at 0.40 A, at 23 ℃) |
0.9 W※3 (at 23 ℃) |
PRCP-RM012/240 | 240 VAC | 265 VAC | 1.2 A | 0.12 A (at 23 ℃) | 0.30 A (at 23 ℃) | 3.00 Ω※1 (at 23 ℃) | 12.00 Ω※2 (at 23 ℃) | 15.0 Sec (at 0.60 A, at 23 ℃) |
1.0 W※3 (at 23 ℃) |
PRCP-RM016/240 | 240 VAC | 265 VAC | 2.0 A | 0.16 A (at 23 ℃) | 0.37 A (at 23 ℃) | 2.50 Ω※1 (at 23 ℃) | 7.80 Ω※2 (at 23 ℃) | 15.0 Sec (at 0.80 A, at 23 ℃) |
1.4 W※3 (at 23 ℃) |
PRCP-RM025/240 | 240 VAC | 265 VAC | 3.5 A | 0.25 A (at 23 ℃) | 0.56 A (at 23 ℃) | 1.30 Ω※1 (at 23 ℃) | 3.80 Ω※2 (at 23 ℃) | 18.5 Sec (at 1.25 A, at 23 ℃) |
1.5 W※3 (at 23 ℃) |
PRCP-RM033/240 | 240 VAC | 265 VAC | 4.5 A | 0.33 A (at 23 ℃) | 0.74 A (at 23 ℃) | 0.77 Ω※1 (at 23 ℃) | 2.60 Ω※2 (at 23 ℃) | 21.0 Sec (at 1.65 A, at 23 ℃) |
1.7 W※3 (at 23 ℃) |
PRCP-RM040/240 | 240 VAC | 265 VAC | 5.5 A | 0.40 A (at 23 ℃) | 0.90 A (at 23 ℃) | 0.60 Ω※1 (at 23 ℃) | 1.90 Ω※2 (at 23 ℃) | 24.0 Sec (at 2.00 A, at 23 ℃) |
2.0 W※3 (at 23 ℃) |
PRCP-RM055/240 | 240 VAC | 265 VAC | 7.0 A | 0.55 A (at 23 ℃) | 1.25 A (at 23 ℃) | 0.45 Ω※1 (at 23 ℃) | 1.45 Ω※2 (at 23 ℃) | 26.0 Sec (at 2.75 A, at 23 ℃) |
3.4 W※3 (at 23 ℃) |
Thermal Derating Chart
Model | Ambient operating temperature: Ihold (A) | ||||||||
---|---|---|---|---|---|---|---|---|---|
-20 ℃ | 0 ℃ | 23 ℃ | 40 ℃ | 50 ℃ | 60 ℃ | 70℃ | 85 ℃ | ||
PRCP-RM005/240 | -20 ℃: 0.08 | 0 ℃: 0.06 | 23 ℃: 0.05 | 40 ℃: 0.04 | 50 ℃: 0.04 | 60 ℃: 0.03 | 70 ℃: 0.03 | 85 ℃: 0.02 | |
PRCP-RM008/240 | -20 ℃: 0.12 | 0 ℃: 0.10 | 23 ℃: 0.08 | 40 ℃: 0.07 | 50 ℃: 0.06 | 60 ℃: 0.05 | 70 ℃: 0.04 | 85 ℃: 0.03 | |
PRCP-RM012/240 | -20 ℃: 0.18 | 0 ℃: 0.15 | 23 ℃: 0.12 | 40 ℃: 0.10 | 50 ℃: 0.09 | 60 ℃: 0.07 | 70 ℃: 0.06 | 85 ℃: 0.04 | |
PRCP-RM016/240 | -20 ℃: 0.24 | 0 ℃: 0.20 | 23 ℃: 0.16 | 40 ℃: 0.13 | 50 ℃: 0.11 | 60 ℃: 0.10 | 70 ℃: 0.08 | 85 ℃: 0.05 | |
PRCP-RM025/240 | -20 ℃: 0.38 | 0 ℃: 0.32 | 23 ℃: 0.25 | 40 ℃: 0.21 | 50 ℃: 0.18 | 60 ℃: 0.15 | 70 ℃: 0.13 | 85 ℃: 0.09 | |
PRCP-RM033/240 | -20 ℃: 0.50 | 0 ℃: 0.42 | 23 ℃: 0.33 | 40 ℃: 0.27 | 50 ℃: 0.23 | 60 ℃: 0.20 | 70 ℃: 0.17 | 85 ℃: 0.11 | |
PRCP-RM040/240 | -20 ℃: 0.61 | 0 ℃: 0.51 | 23 ℃: 0.40 | 40 ℃: 0.33 | 50 ℃: 0.28 | 60 ℃: 0.24 | 70 ℃: 0.20 | 85 ℃: 0.14 | |
PRCP-RM055/240 | -20 ℃: 0.80 | 0 ℃: 0.68 | 23 ℃: 0.55 | 40 ℃: 0.46 | 50 ℃: 0.40 | 60 ℃: 0.35 | 70 ℃: 0.29 | 85 ℃: 0.22 |
Environmental Characteristics
Operating Temperature | -20 ℃ ~ +85 ℃ |
---|---|
Passive Aging | 85 ℃, 1000 h: ±20 % typical resistance change |
Humidity Aging | 85 ℃, 85 %RH, 1000 h: ±20 % typical resistance change |
Thermal Shock | -40 ℃ ~ +85 ℃, 10 cycles: ±15 % typical resistance change |
Solvent Resistance |
MIL-STD-202 method 215: No change |
Vibration | MIL-STD-883C, Method 2007.1, Condition A: No change |
MSL (Moisture Sensitivity Level) | Level 1, J-STD-020 |
Test Procedures and Requirements
Item | Test Condition | Accept / Reject Criteria |
---|---|---|
Visual/Mech. | Verify dimensions and materials | Per P.R.C.P. physical description |
Resistance | Test condition: In still air @ 23 ℃ | Accept / Reject criteria: R min ≤ R ≤ R1 max |
Time to Trip | Test condition: 240 Vac, specified current | Accept / Reject criteria: T ≤ max. time to trip (Sec) |
Hold Current | Test condition: 30 min. at Ihold , 23 ℃, still air | Accept / Reject criteria: No trip |
Trip Cycle Life | Test condition: 240 Vac, I max , 100 cycles | Accept / Reject criteria: No arcing or burning |
Trip Endurance | Test condition: a) 240 Vac, I max, 24 h b) 265 Vac, I max, 30 min |
Accept / Reject criteria: No arcing or burning |
Solderability | Test condition: 245 ℃ ± 5 ℃, 5 seconds | Accept / Reject criteria: 95% min. coverage |
Product Dimensions
Model | A | B | C | D | E | Style | |
---|---|---|---|---|---|---|---|
Max. | Max. | Nom. | Tol. ± | Min. | Max. | ||
PRCP-RM005/240 | 8.3 (0.327) |
12.9 (0.508) |
5.1 (0.201) |
0.7 (0.028) |
7.6 (0.299) |
3.8 (0.150) |
Style 1 |
PRCP-RM008/240 | 8.3 (0.327) |
12.9 (0.508) |
5.1 (0.201) |
0.7 (0.028) |
7.6 (0.299) |
3.8 (0.150) |
Style 1 |
PRCP-RM012/240 | 8.3 (0.327) |
12.9 (0.508) |
5.1 (0.201) |
0.7 (0.028) |
7.6 (0.299) |
3.8 (0.150) |
Style 1 |
PRCP-RM016/240 | 9.9 (0.390) |
13.8 (0.543) |
5.1 (0.201) |
0.7 (0.028) |
7.6 (0.299) |
3.8 (0.150) |
Style 1 |
PRCP-RM025/240 | 10.0 (0.394) |
20.0 (0.787) |
5.1 (0.201) |
0.7 (0.028) |
7.6 (0.299) |
3.8 (0.150) |
Style 2 |
PRCP-RM033/240 | 11.4 (0.449) |
20.0 (0.787) |
5.1 (0.201) |
0.7 (0.028) |
7.6 (0.299) |
3.8 (0.150) |
Style 2 |
PRCP-RM040/240 | 11.5 (0.453) |
20.9 (0.823) |
5.1 (0.201) |
0.7 (0.028) |
7.6 (0.299) |
3.8 (0.150) |
Style 2 |
PRCP-RM055/240 | 14.0 (0.551) |
22.4 (0.882) |
5.1 (0.201) |
0.7 (0.028) |
7.6 (0.299) |
4.1 (0.161) |
Style 2 |
PRCP-RM005/240 |
Style:Style 1
A:Max. 8.3 (0.327) B:Max. 12.9 (0.508) C:Nom. 5.1 (0.201) C:Tol. ± 0.7 (0.028) D:Min. 7.6 (0.299) E:Max. 3.8 (0.150) |
---|---|
PRCP-RM008/240 |
Style:Style 1
A:Max. 8.3 (0.327) B:Max. 12.9 (0.508) C:Nom. 5.1 (0.201) C:Tol. ± 0.7 (0.028) D:Min. 7.6 (0.299) E:Max. 3.8 (0.150) |
PRCP-RM012/240 |
Style:Style 1
A:Max. 8.3 (0.327) B:Max. 12.9 (0.508) C:Nom. 5.1 (0.201) C:Tol. ± 0.7 (0.028) D:Min. 7.6 (0.299) E:Max. 3.8 (0.150) |
PRCP-RM016/240 |
Style:Style 1
A:Max. 9.9 (0.390) B:Max. 13.8 (0.543) C:Nom. 5.1 (0.201) C:Tol. ± 0.7 (0.028) D:Min. 7.6 (0.299) E:Max. 3.8 (0.150) |
PRCP-RM025/240 |
Style:Style 2
A:Max. 10.0 (0.394) B:Max. 20.0 (0.787) C:Nom. 5.1 (0.201) C:Tol. ± 0.7 (0.028) D:Min. 7.6 (0.299) E:Max. 3.8 (0.150) |
PRCP-RM033/240 |
Style:Style 2
A:Max. 11.4 (0.449) B:Max. 20.0 (0.787) C:Nom. 5.1 (0.201) C:Tol. ± 0.7 (0.028) D:Min. 7.6 (0.299) E:Max. 3.8 (0.150) |
PRCP-RM040/240 |
Style:Style 2
A:Max. 11.5 (0.453) B:Max. 20.9 (0.823) C:Nom. 5.1 (0.201) C:Tol. ± 0.7 (0.028) D:Min. 7.6 (0.299) E:Max. 3.8 (0.150) |
PRCP-RM055/240 |
Style:Style 2
A:Max. 14.0 (0.551) B:Max. 22.4 (0.882) C:Nom. 5.1 (0.201) C:Tol. ± 0.7 (0.028) D:Min. 7.6 (0.299) E:Max. 4.1 (0.161) |
Warranty
However, the following shall be excluded from the warranty:
Failure or damage caused by improper use and careless operation in violation of the catalog and specification.
The term “Warranty” herein referred to shall imply the warranty for the product unit only, and damages from failure of the product shall be excluded.
This product is not intended to be used for equipment that may cause direct harm to life or body, or equipment that may cause significant physical damage. (Aerospace and space related equipment, railway vehicles, nuclear power equipment, military equipment, etc.) We are not liable for any damages arising from the use of this product for purposes not intended by us.
Furthermore, we ask you to perform a swift incoming inspection for delivered products and we wouldalso appreciate if full attention is given to the storage conditions of the product.
Documents
Environmental Data
- ●The above contents and descriptions are subject to change without notice.