Druckmessgerät PG-200
- ●Um einen Kauf zu tätigen, wenden Sie sich an die Verteiler unten.
Verkaufskanal Überprüfen Sie die Verteiler.- VERKAUFSKANALKlicken Sie hier, um den Verteiler zu überprüfen.
Pressure gauge PG-200
- Excellent stability
A semiconductor chip is used as pressure a sensing element. State of the art circuit technology guarantees excellent temperature compensation. - Low power consumption
Approx. 9000 hours (one year) continuous operation by 3.6 V lithium battery is expected due to the adoption time sharing operation method. - Easy reading with a large LCD display
- With pressure switches function
Two independent pressure setting points of HI and LO - With analog output (0 ~ 1 V)
- Meets DIN sizes W72 × H72 × D40 mm
- PG-200 is for non-corrosive gases.
STANDARD SPECIFICATIONS[Pa version]
- Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C, excitation voltage of 12 V DC and battery of 3.6 VDC.
● General specifications
Pressure reference | Gauge | Absolute | ||||
---|---|---|---|---|---|---|
Model number (Pa unit display) | 101GP | 102GP | 103GP | 102VP | 102AP | |
103GMP | ||||||
Rated pressure range | 10kPa | 100kPa | 1000kPa | -100kPa | 100 kPa(abs) | |
Maximum pressure | 20kPa | 200kPa | 1500kPa | 200kPa | 200 kPa(abs) | |
Break-dawn pressure | 50kPa | 500kPa | 2000kPa | 500kPa | 500 kPa(abs) | |
Operating temp., range | 0 ~ 50°C | |||||
Compensated temp. range | 0 ~ 50°C | |||||
Operating humidity | 35 ~ 85%RH(No condensation) | |||||
Storage temp. | − 20 ~ 70°C(Atmospheric pressure, humidity 65 %RH maximum) | |||||
Pressure medium | Non-corrosive gases | |||||
Pressure port | Panel type | M 5 | ||||
Stand type | R 1/4(PT 1/4) | |||||
Net weight | Panel type | Approx. 130g | ||||
Stand type | Approx. 330g | |||||
Power | Battery type |
Lithium battery DC 3.6 V (ER6VM) Battery life 9000 h minimum |
||||
External power |
DC5〜10 V、DC10〜24 V |
● Display
Pressure reference | Gauge | Absolute | ||||
---|---|---|---|---|---|---|
Model number (Pa unit display) | 101GP | 102GP | 103GP | 102VP | 102AP | |
103GMP | ||||||
Display cycle | Approx. 3 times/s | |||||
Display accuracy | ± 0.5 %F.S. ± 2 counts (at 25 ± 5 °C) maximum |
|||||
Thermal error | ZERO | ± 0.1 % F.S./°C maximum | ± 0.05 % F.S./°C ± 2 counts maximum |
± 0.1 % F.S./°C ± 2 counts maximum |
||
SPAN | ± 0.05 % Reading/°C ± 2 counts | |||||
Resolution | 1 count |
● Switch
Pressure reference | Gauge | Absolute | ||||
---|---|---|---|---|---|---|
Model number (Pa unit display) | 101GP | 102GP | 103GP | 102VP | 102AP | |
103GMP | ||||||
Resolution | 1 count | |||||
No. of setting points | 2 points of HI and LO (one point of HI only for the external power supply version) |
|||||
Switching capacity | 30 VDC、40 mA(NPN open collector) | |||||
Residual voltage | 1.2 VDC(When current inflow is 40 mA) | |||||
Output conditions | Measured press ≧ LO set press. → LO output ON, Measured press. ≧ HI set press. → HI output ON. |
|||||
Setting method | When the SET button is pressed, HI set pressure is displayed for about 20 seconds first, then LO set pressure is displayed for about 20 seconds. Therefore, high and low pressure settings can be made by VR watching the display |
|||||
Pressure setting range (Pa unit display) |
0.00~10.00kPa | 00.0~100.0kPa | 000~1000kPa | 00.0~ − 100.0kPa |
00.0~ 100.0kPa |
|
.000~1.000 (MPa) |
||||||
Switch state indication | Indicated by an LCD display (HI or LO) when the switch output is ON. |
|||||
Response | Approx. 100 ms | |||||
Switching hysteresis | 4 counts maximum | |||||
Analog voltage output ※1 |
Voltage output: 0 ~ 1 V, Accuracy: ± 1 %F.S. (at 25 ± 5 °C), Load: 1 kΩ minimum |
|||||
Additional function | Low battery indication (LO BAT) | |||||
Accessories (for panel type only) |
Attachements : Half union (for a tube of φ 6 0.D.), and Barb fitting (for a tube of φ 4 I.D.), one piece each.(Panel type only) |
- ※ 1 : Available only for external power type.
STANDARD SPECIFICATIONS[Non SI unit version]
- Unless otherwise specified, the specs are defined at an ambient temperature of 25 ± 5 °C, excitation voltage of 12 V DC and battery of 3.6 VDC.
◆ General specifications
Pressure reference | Gauge | Absolute | ||||
---|---|---|---|---|---|---|
Model number | 101G | 102G | 103G | 102VH | 102AH | |
Rated pressure range kPa{kgf/cm2} |
9.81 {1000 mmH2O} |
98.1 {1} |
981 {10} |
-98.1 {-735 mmHg} |
98.1 kPa abs {735 mmHg abs} |
|
Maximum pressure kPa{kgf/cm2} |
19.6 {2000 mmH2O} |
196 {2} |
1471 {15} |
196 {1471 mmHg} |
196 kPa abs {1471 mmHg abs} |
|
Break-dawn pressure kPa{kgf/cm2} |
49.0 {5000 mmH2O} |
490 {5} |
1961 {20} |
490 {3678 mmHg} |
490 kPa abs {3678 mmHg abs} |
|
Operating temp., range | 0~50°C | |||||
Compensated temp. range | 0~50°C | |||||
Operating humidity | 35~85%RH(No condensation) | |||||
Storage temp. | -20~70°C (Atmospheric pressure, humidity 65 %RH maximum) |
|||||
Pressure medium | Non-corrosive gases | |||||
Pressure port | Panel type | M 5 | ||||
Stand type | R 1/4(PT 1/4) | |||||
Net weight | Panel type | Approx. 130g | ||||
Stand type | Approx. 330g | |||||
Power | Battery type | Lithium battery DC 3.6 V (ER6VM) Battery life 9000 h minimum |
||||
External power | DC5~10 V、DC10~24 V (Selectable by electrical treminals only in case of stand type) Consumption current : 20 mA maximum |
◆ Display
Pressure reference | Gauge | Absolute | ||||
---|---|---|---|---|---|---|
Model number | 101G | 102G | 103G | 102VH | 102AH | |
No. of digits | 3 1/2 | |||||
Display element | LCD | |||||
Rated display range | 000~1000 mmH2O | .000~1.000 kgf/cm2 | 0.00~10.00 kgf/cm2 | 000~-735 ※ 2 mmHg | 000~735 ※ 2 mmHg | |
Display cycle | Approx. 3 times/s | |||||
Display accuracy | ± 0.5 %F.S. ± 2 counts (at 25 ± 5 °C) maximum | |||||
Thermal error | ZERO | ± 0.1 % F.S./°Cmaximum | ± 0.05 % F.S./°C ± 2 counts maximum | ± 0.1 % F.S./°C ± 2 counts maximum | ||
SPAN | ± 0.05 % Reading/°C ± 2 counts | |||||
Resolution | 1 count |
◆ Switch
Pressure reference | Gauge | Absolute | ||||
---|---|---|---|---|---|---|
Model number | 101G | 102G | 103G | 102VH | 102AH | |
No. of setting points | 2 points of HI and LO (one point of HI only for the external power supply version) |
|||||
Switching capacity | 30 V DC、40 mA(NPN open collector) | |||||
Residual voltage | 1.2 V DC(When current inflow is 40 mA) | |||||
Output conditions | Measured press ≧ LO set press. → LO output ON, Measured press. ≧ HI set press. → HI output ON. |
|||||
Setting method | When the SET button is pressed, HI set pressure is displayed for about 20 seconds first, then LOset pressure is displayed for about 20 seconds. Therefore, high and low pressure settings can be made by VR watching the display. |
|||||
Pressure setting range | 000~1000kPa | .000~1.000kPa | 0.00~10.00kPa | 000~ -735 ※ 3 | 000~735 ※ 3 | |
Switch state indication | Indicated by an LCD display (HI or LO) when the switch output is ON. |
|||||
Response | Approx. 100 ms | |||||
Switching hysteresis | 4 counts maximum | |||||
Analog voltage output ※ 1 | Voltage output: 0 ~ 1 V, Accuracy: ± 1 %F.S. (at 25 ± 5 °C), Load: 1 kΩ minimum |
|||||
Additional function | Low battery indication (LO BAT) | |||||
Accessories (for panel type only) |
Attachements : Half union (for a tube of φ 6 0.D.), and Barb fitting (for a tube of φ 4 I.D.), one piece each. (Panel type |
- ※ 1:Available only for external power type.
- ※ 2 : Measurement can be made up to “- 760 mmHg” for 102VH and up to “760 mmHg” for 102AH (Accuracy not guaranteed beyond the rated pressure.).
- ※ 3 : Pressure setting can be made up to “– 760 mmHg” for 102VH and up to “760 mmHg” for 102AH (Accuracy not guaranteed beyond the rated pressure.).
MODEL NUMBER DESIGNATION
PG-200- | 102 | G P- | 3 - | P |
---|---|---|---|---|
Series name |
Rated pressure range 101:0~9.81 kPa {0~0.1 kgf/cm2} 0~10 kPa (Pa unit display) {0~1 kgf/cm2} 0~100 kPa (Pa unit display) {0~10 kgf/cm2} 0~1 MPa (Pa unit display) |
Pressure reference G:Gauge GMP:Gauge(103 type only) |
Power Blank:Battery |
Installation P:Panel type |
LIST OF MODEL NUMBERS
●Pa version
Model number | Pressure reference | Rated pressure (Pa unit display) | Unit of display | Pressure medium | Installation | Power | CAD |
---|---|---|---|---|---|---|---|
PG-200-101GP-1P | Gauge | 0~10 | kPa | For non-corrosive gases | Panel type | Battery | |
PG-200-101GP-3-P | Gauge | 0~10 | kPa | For non-corrosive gases | Panel type | External power | |
PG-200-101GP-S | Gauge | 0~10 | kPa | For non-corrosive gases | Stand type | Battery | |
PG-200-101GP-3-S | Gauge | 0~10 | kPa | For non-corrosive gases | Stand type | External power | |
PG-200-102GP-P | Gauge | 0~100 | kPa | For non-corrosive gases | Panel type | Battery | |
PG-200-102GP-3-P | Gauge | 0~100 | kPa | For non-corrosive gases | Panel type | External power | |
PG-200-102GP-S | Gauge | 0~100 | kPa | For non-corrosive gases | Stand type | Battery | |
PG-200-102GP-3-S | Gauge | 0~100 | kPa | For non-corrosive gases | Stand type | External power | |
PG-200-103GP-P | Gauge | 0~1000 | kPa | For non-corrosive gases | Panel type | Battery | |
PG-200-103GP-3-P | Gauge | 0~1000 | kPa | For non-corrosive gases | Panel type | External power | |
PG-200-103GP-S | Gauge | 0~1000 | kPa | For non-corrosive gases | Stand type | Battery | |
PG-200-103GP-3-S | Gauge | 0~1000 | kPa | For non-corrosive gases | Stand type | External power | |
PG-200-102VP-P | Gauge | 0~− 100 | kPa | For non-corrosive gases | Panel type | Battery | |
PG-200-102VP-3-P | Gauge | 0~− 100 | kPa | For non-corrosive gases | Panel type | External power | |
PG-200-102VP-S | Gauge | 0~− 100 | kPa | For non-corrosive gases | Stand type | Battery | |
PG-200-102VP-3-S | Gauge | 0~− 100 | kPa | For non-corrosive gases | Stand type | External power | |
PG-200-102AP-P | Absolute | 0~100 kPa abs | kPa abs | For non-corrosive gases | Panel type | Battery | |
PG-200-102AP-3-P | Absolute | 0~100 kPa abs | kPa abs | For non-corrosive gases | Panel type | External power | |
PG-200-102AP-S | Absolute | 0~100 kPa abs | kPa abs | For non-corrosive gases | Stand type | Battery | |
PG-200-102AP-3-S | Absolute | 0~100 kPa abs | kPa abs | For non-corrosive gases | Stand type | External power |
●Non SI unit version
Model number | Pressure reference | Rated pressure kPa {kgf/cm2} | Unit of display | Pressure medium | Installation | Power | CAD |
---|---|---|---|---|---|---|---|
PG-200-101G-P | Gauge | 0~9.81{0~1000 mmH2O} | mmH2O | For non-corrosive gases | Panel type | Battery | |
PG-200-101G-3-P | Gauge | 0~9.81{0~1000 mmH2O} | mmH2O | For non-corrosive gases | Panel type | External power | |
PG-200-101G-S | Gauge | 0~9.81{0~1000 mmH2O} | mmH2O | For non-corrosive gases | Stand type | Battery | |
PG-200-101G-3-S | Gauge | 0~9.81{0~1000 mmH2O} | mmH2O | For non-corrosive gases | Stand type | External power | |
PG-200-102G-P | Gauge | 0~98.1{0~1} | kgf/cm2 | For non-corrosive gases | Panel type | Battery | |
PG-200-102G-3-P | Gauge | 0~98.1{0~1} | kgf/cm2 | For non-corrosive gases | Panel type | External power | |
PG-200-102G-S | Gauge | 0~98.1{0~1} | kgf/cm2 | For non-corrosive gases | Stand type | Battery | |
PG-200-102G-3-S | Gauge | 0~98.1{0~1} | kgf/cm2 | For non-corrosive gases | Stand type | External power | |
PG-200-103G-P | Gauge | 0~981{0~10} | kgf/cm2 | For non-corrosive gases | Panel type | Battery | |
PG-200-103G-3-P | Gauge | 0~981{0~10} | kgf/cm2 | For non-corrosive gases | Panel type | External power | |
PG-200-103G-S | Gauge |
0~981{0~10} |
kgf/cm2 | For non-corrosive gases | Stand type | Battery | |
PG-200-103G-3-S | Gauge | 0~981{0~10} | kgf/cm2 | For non-corrosive gases | Stand type | External power | |
PG-200-102VH-P | Gauge | 0~− 98.1 {0~- 735 mmHg} | mmHg | For non-corrosive gases | Panel type | Battery | |
PG-200-102VH-3-P | Gauge | 0~− 98.1 {0~- 735 mmHg} | mmHg | For non-corrosive gases | Panel type | External power | |
PG-200-102VH-S | Gauge | 0~− 98.1 {0~- 735 mmHg} | mmHg | For non-corrosive gases | Stand type | Battery | |
PG-200-102VH-3-S | Gauge | 0~− 98.1 {0~- 735 mmHg} | mmHg | For non-corrosive gases | Stand type | External power | |
PG-200-102AH-P | Absolute | 0~98.1 kPa abs {0~735 mmHg abs} | mmHg | For non-corrosive gases | Panel type | Battery | |
PG-200-102AH-3-P | Absolute | 0~98.1 kPa abs {0~735 mmHg abs} | mmHg | For non-corrosive gases | Panel type | External power | |
PG-200-102AH-S | Absolute | 0~98.1 kPa abs {0~735 mmHg abs} | mmHg | For non-corrosive gases | Stand type | Battery | |
PG-200-102AH-3-S | Absolute | 0~98.1 kPa abs {0~735 mmHg abs} | mmHg | For non-corrosive gases | Stand type | External power |
- 〈Option〉---DC3.6 V lithium batteryーOrder item: Lithium battery
- The battery is an expendable item.The first one is provided with the unit.
ENVIRONMENTAL CHARACTERISTICS
Test item | Test conditions | Permissible change |
---|---|---|
Vibration | Amplitude 1.5 mm P-P, 10 ~ 55 Hz, 3 directions for 2 hours each (packed) |
Pressure indication, switch setting and analog output (zero and span) variation: ± 1 %F.S. maximum each. (Note: No analog output for the battery type.) |
Shock | 98.1 m/s2 , 3 directions for 3 times each (packed) | |
Moisture resistance | 40 °C, 90 ~ 95 %RH, 240 hrs | |
Pressure cycling | 0 ~ Rated pressure, 106 cycles |
INTERNAL ELECTRICAL SCHEMATICS
INSIDE OF A PANEL
OUTLINE DIMENSIONS
Unless otherwise specified, tolerance : ± 0.5 (Unit: mm)
※Extra care should be taken with the diaphragm part. Do not touch the diaphragm directly to avoid damaging the diaphragm.
Unterlagen
- ●Die oben genannten Inhalte können ohne vorherige Ankündigung geändert werden.