Pressure transducer with amp. PA-800
PRESSURE TRANSDUCERS WITH AMP. PA-800
- High corrosion resistance by double diaphragm structure
- Built-in amplifier circuit
- Built-in temperature compensation function (0 ~ 50 °C)
- Voltage output mode
Standard specifications
Operating temp. range | −20 ~ 70°C |
---|---|
Compensated temp. range | 0 ~ 50°C |
Operating humidity | 35 ~ 85%RH(No condensation) |
Storage temp. | −20 ~ 80°C(Atmospheric pressure, humidity 65 %RH maximum) |
Pressure medium | Corrosive gases/liquids compatible with SUS316L and SUS304 |
Insulation resistance | 100 (500 V DC)MΩ min. |
Dielectric strength | 500 V AC, 60 s(Leakage current 1 mA maximum) |
Sealed liquid | Silicone oil |
Pressure port | G 3/8 (PF 3/8) An “O” ring is provided. (P18) |
Supply voltage | 12 ~ 24 ± 10 %V DC |
Ripple content | 10 % (P-P)maximum |
Consumption current | 20mA maximum |
Net weight | Approx. 125g |
Analog output
Pressure range | 102G | 102V | 352G | 103G |
---|---|---|---|---|
Output voltage | 1 ~ 5V DC | |||
Zero voltage | 1 ± 0.04V (at 25 °C) | |||
Span voltage | 4 ± 0.04V (at 25 °C) | |||
Output current | 1mA maximum(Load resistance 5 kΩ minimum) | |||
Linearity/Hysteresis | ± 0.3%F.S. | ± 0.5%F.S. | ||
Thermal error 0 ~ 50 °C |
ZERO:± 0.05/± 0.1%F.S./°C SPAN:± 0.05/± 0.1%F.S./°C | |||
Supply voltage effect | ± 0.1V maximum | |||
Response | Approx. 2ms | |||
Gravitational effect (From vertical position to horizontal position) |
Approx. 0.5%F.S.max. | Approx. 0.15%F.S.max. | Approx. 0.05%F.S.max. |
Model Number Designation
PA-800- | 102 | G- | 05 |
---|---|---|---|
Series name |
Rated pressure range 102:0 ~ 98.1 kPa {0 ~ 1 kgf/cm2} |
Pressure reference G:Gauge |
Thermal error 05:0.05 % F.S./°C |
List of model numbers
Model numbers | Pressure reference | Rated pressure | Maximum pressure | Break-down pressure | Thermal error | CAD |
---|---|---|---|---|---|---|
PA-800-102G-05 | Gauge | 98.1{1}kPa {kgf/cm2} | 196{2}kPa {kgf/cm2} | 294{3}kPa {kgf/cm2} | 0.05 % F.S./°C | |
PA-800-102G-10 | Gauge | 98.1{1}kPa {kgf/cm2} | 196{2}kPa {kgf/cm2} | 294{3}kPa {kgf/cm2} | 0.1 % F.S./°C | |
PA-800-102V-05 | Gauge | -98.1{-1}kPa {kgf/cm2} | 196{2}kPa {kgf/cm2} | 294{3}kPa {kgf/cm2} | 0.05 % F.S./°C | |
PA-800-102V-10 | Gauge | -98.1{-1}kPa {kgf/cm2} | 196{2}kPa {kgf/cm2} | 294{3}kPa {kgf/cm2} | 0.1 % F.S./°C | |
PA-800-352G-05 | Gauge | 343{3.5}kPa {kgf/cm2} | 686{7}kPa {kgf/cm2} | 1030{10.5}kPa {kgf/cm2} | 0.05 % F.S./°C | |
PA-800-352G-10 | Gauge | 343{3.5}kPa {kgf/cm2} | 686{7}kPa {kgf/cm2} | 1030{10.5}kPa {kgf/cm2} | 0.1 % F.S./°C | |
PA-800-103G-05 | Gauge | 981{10}kPa {kgf/cm2} | 1961{20}kPa {kgf/cm2} | 2942{30}kPa {kgf/cm2} | 0.05 % F.S./°C | |
PA-800-103G-10 | Gauge | 981{10}kPa {kgf/cm2} | 1961{20}kPa {kgf/cm2} | 2942{30}kPa {kgf/cm2} | 0.1 % F.S./°C |
Environment Characteristics
Test item | Test conditions (At 25 ± 5 °C) | Permissible change |
---|---|---|
Vibration | 10 ~ 500 Hz, 1.5 mm maximum/98.1 m/s2 , 3 directions for 2 hours each |
Zero voltage, Span voltage: ± 1 %F.S. maximum each |
Shock | 981 m/s2 , 3 directions for 3 times each | |
Pressure cycling | 0 ~ Rated pressure, 106 cycles | |
Moisture resistance | 40 °C, 90 ~ 95 %RH, 240 hrs. |
Outline Dimensions
Internal circuit diagram
Documents
- ●The above contents and descriptions are subject to change without notice.